5-Port Solenoid Valve With Single/Double Switch Function

Caution
- Refer to the manufacturer's catalog for specification and material details.
- Product images may be representative images. Refer to the manufacturer's catalog for shape details.
Product Description
Choose between single and double solenoids by using a switch.
[Features]
· Rated voltage: 24 V DC.
· Pilot valve option: Standard (0.7 MPa), Quick response (0.7 MPa).
· Back-pressure check valve (built-in valve type): Standard, built-in.
· Coil type: Standard, with power-saving circuit (continuous duty type).
· Common specifications: Non-polar, positive common, negative common.
5-Port Solenoid Valve With Single / Double Switching Function Specifications

5-Port Solenoid Valve With Single / Double Switching Function external appearance
- Valve type: Pilot operated 2-position 5-port solenoid valve
- Valve construction: Rubber seal
- Switching method: Single/double switching type
- Piping: Side ported / bottom ported, top ported
- Manual: Non-locking push type, push-turn locking slotted type, push-turn locking lever type, sliding lock type
Base mounted valve weight
- SY3(S, D)00: 84.5 g
- SY5(S, D)00: 95.3 g
Body ported valve weight
- SY3S30 (port size: C4): 87.9 g
- SY3S30 (piping connection port diameter: C6): 90.9 g
- SY5D30 (piping connection port diameter: C8): 112.3 g
*This product is the valve unit only. The manifold is not included.
Actuation switch

Single solenoid

Double solenoid

Switching between single specification and double specification (Left: single specification / actuation switch recessed, Right: double specification / actuation switch protruding)
Usage Precautions
- 1.When using a single specification valve as a double specification, turn the actuation switch with a precision screwdriver so that the slot on the actuation switch is in the "S" position as shown in the drawing.
- 2.When using a double specification valve as a single specification, press the actuation switch and then rotate it counterclockwise. The single specification will not malfunction even if the 2 (B) side is operated manually.
- 3.Do not energize the solenoid on both sides simultaneously.
- 4. Be aware that actuator ejection may occur if the actuation switch of the double specification is operated when the main valve position is connecting 1 (P) → 4 (A), as the main valve position will change to connecting 1 (P) → 2 (B).
- 5.See the manufacturer's catalog for details regarding the electric circuitry of models with indicator light / surge voltage suppressor.
- 6.For manifold piping specification, select double piping specification.
- 7.When turning the conversion switch, do not apply more torque than required. (Recommended value: less than 0.05 N⋅m)
Outline dimensional drawing
Side/bottom ported type
(Unit: mm)

SY3(S, D)00 dimensional drawing
(Unit: mm)

SY5(S, D)00 dimensional drawing
Top ported type
(Unit: mm)

SY3(S, D)30 dimensional drawing
(Unit: mm)

SY5(S, D)30 dimensional drawing
*Dimensional drawings are of a representative product.
Precautions
- *Product images may be representative images.
- *See the manufacturer's catalog for product information other than the above.