(!) Since support from Microsoft will end on January 14 2020, Windows 7 user might not be able to use MISUMI website effectively. Please consider to update your system as ‘MISUMI Website system requirement’.
Select part number to Order Now/ Add to Cart
Compatible with Japan's Food Sanitation Law.
[Features]
· Flexibility: Improved by approx. 20%.
· Operating temperature: Max. 260°C.
[Applications]
· Suitable for applications which require flexibility.
Size | Metric Size | |||||
---|---|---|---|---|---|---|
Nominal | TD0425 | TD0604 | TD0806 | TD1075 | TD1209 | |
Outer diameter (mm) | 4 | 6 | 8 | 10 | 12 | |
Inner diameter (mm) | 2.5 | 4 | 6 | 7.5 | 9 | |
Roll | 10 m | ● | ● | ● | ● | ● |
20 m | ● | ● | ● | ● | ● | |
Color | Translucent (material color) | |||||
Applicable Fluids | See the catalog for applicable fluids. | |||||
FluidNote 1) | Air, waterNote 1), inert gas | |||||
Applicable fittingsNote 1) | Insert fittings KF Series Stainless steel 316 insert fittings KFG Series Miniature fittings M, MS Series (Hose-nipple type) Fluoropolymer fittings LQ Series | |||||
Maximum operating pressure (MPa) | 20°C | 1.6 | 1.4 | 0.9 | 0.9 | 0.9 |
100°C | 0.9 | 0.7 | 0.5 | 0.5 | 0.5 | |
200°C | 0.45 | 0.35 | 0.25 | 0.25 | 0.25 | |
260°C | 0.23 | 0.2 | 0.15 | 0.15 | 0.15 | |
Minimum bending radius mmNote 3) | Recommended radius | 15 | 25 | 45 | 55 | 75 |
Tube close bend radius | 8 | 16 | 31 | 35 | 41 | |
Maximum operating temperature (fixed usage) | 260°C | |||||
Material | Modified PTFE (Polytetrafluoroethylene resin) |
Note 1) When using a liquid fluid, the surge pressure must be under the maximum operating pressure. If the surge pressure exceeds the maximum operating pressure, it will result in damage to the fittings and tubing. Furthermore, abnormal temperature rise caused by adiabatic compression may result in the tubing bursting.
Note 2) Do not use this product in a manner in which the tubing is not fixed. Observe the lesser value of the maximum operating pressure between the tubing and fittings. A material change over a long duration or due to high temperature may cause leakage. Perform periodic maintenance and replace with a new product immediately when abnormalities are detected.
Note 3) The minimum bending radius is the representative value measured as shown in the figure on the left.
How to measure the minimum bending radius
Bend the tubing into a U shape at a temperature of 20°C. Fix one end and close the loop gradually. Measure 2R when the deformed ratio of the tubing diameter at bending reaches 5%.
Maximum operating pressure
Size | Inch Size | |||||
---|---|---|---|---|---|---|
Nominal | TID01 | TID05 | TID07 | TID11 | TID13 | |
Outer diameter | inch | 1/8 " | 3/16 " | 1/4 " | 3/8 " | 1/2 " |
mm | 3.18 | 4.75 | 6.35 | 9.53 | 12.7 | |
Inner diameter | inch | 0.086 " | 0.124 " (1/8 ") | 0.156 " (5/32 ") | 0.25 " (1/4 ") | 0.374 " (3/8 ") |
mm | 2.18 | 3.15 | 3.95 | 6.33 | 9.5 | |
Roll | 8 m (25 ft) | ● | ● | ● | ● | ● |
16 m (50 ft) | ● | ● | ● | ● | ● | |
Color | Translucent (material color) | |||||
Applicable Fluids | See the catalog for applicable fluids. | |||||
FluidNote 1) | Air, waterNote 1), inert gas | |||||
Applicable fittingsNote 2) | Fluoropolymer Fittings LQ Series | |||||
Maximum operating pressure (MPa) | 20°C | 1.4 | 1.4 | 1.6 | 1.4 | 0.9 |
100°C | 0.7 | 0.7 | 0.9 | 0.7 | 0.5 | |
200°C | 0.35 | 0.35 | 0.45 | 0.35 | 0.25 | |
260°C | 0.2 | 0.2 | 0.23 | 0.2 | 0.15 | |
Minimum bending radius mmNote 3) | Recommended radius | 15 | 20 | 25 | 40 | 75 |
Tube close bend radius | 9 | 10 | 15 | 23 | 42 | |
Maximum operating temperature (fixed usage) | 260°C | |||||
Material | Modified PTFE (Polytetrafluoroethylene resin) |
Note 1) When using a liquid fluid, the surge pressure must be under the maximum operating pressure. If the surge pressure exceeds the maximum operating pressure, it will result in damage to the fittings and tubing. Furthermore, abnormal temperature rise caused by adiabatic compression may result in the tubing bursting.
Note 2) Do not use this product in a manner in which the tubing is not fixed. Observe the lesser value of the maximum operating pressure between the tubing and fittings. A material change over a long duration or due to high temperature may cause leakage. Perform periodic maintenance and replace with a new product immediately when abnormalities are detected.
Note 3) The minimum bending radius is the representative value measured as shown in the figure on the left.
How to measure the minimum bending radius
Bend the tubing into a U shape at a temperature of 20°C. Fix one end and close the loop gradually. Measure 2R when the deformed ratio of the tubing diameter at bending reaches 5%.
Maximum operating pressure
Part Number |
---|
TD0425-10 |
TD0425-20 |
TID01-8 |
TID01-16 |
Part Number | Price | Name | Minimum Order Qty. | Volume Discount | Days to Ship | Outer Dia. D (Ø) | O.D. [Distinction] | Inner Dia. d (Ø) | I.D. [Distinction] | Minimum Bending Radius (mm) | Bundle winding length (m) | Applicable Tube Size | Maximum operating pressure (MPa) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
฿ 2,033.20 | TUBE | 1 Piece(s) | 3 Day(s) | 4 | ~4 | 2.5 | ~3 | 15 | 10 | Metric Size | 1.6 | ||
฿ 4,067.25 | TUBE | 1 Piece(s) | Same day | 4 | ~4 | 2.5 | ~3 | 15 | 20 | Metric Size | 1.6 | ||
฿ 1,142.40 | TUBE | 1 Piece(s) | 29 Day(s) | 3.18 | ~4 | - | ~3 | 15 | 8 | Inch Size | 1.4 | ||
฿ 2,284.80 | TUBE | 1 Piece(s) | 3 Day(s) | 3.18 | ~4 | - | ~3 | 15 | 16 | Inch Size | 1.4 |
Loading...
Type | Straight | Cutting Service Usage | No | Material | Fluororesin |
---|---|---|---|---|---|
Applicable Fluid | Water / Air | Operating Environment | Standard / Chemical Resistance | Color | Translucent (Material Color) |
Material, Fluororesin | Denatured PTFE (Ethylene Resin Tetrafluoride) | Operating temperature(°C) | up to 260 |
How can we improve?