Part Number |
---|
E5AN-HAA2HHBF AC100-240 |
Part Number | Price | Name | Minimum Order Qty. | Volume Discount | Days to Ship | Input Method | Output Type | Number of Control Points | Setting Method | Failure Detecting Function | Power Supply Voltage (V) | Control Output 1 | Control Output 2 | Event Input (Point) | Heater burnout / SSR failure / heater overcurrent detection function | Program type | Specifications | Communication | Transmission Output |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
฿ 20,765.00 ฿ 14,705.77 | Temperature Controllers | 1 Piece(s) | 5 Day(s) | Thermocouple / Platinum temperature measuring resistor | - | - | - | Heater Breakage / Heater Over current / SSR Breakdown | 100 to 240 VAC | Output Unit Method | Output Unit Method | 2 | Detection for single or three-phase heater | - | - | - | - |
Loading...
Control Method | ON/OFF Control / PID control with auto tuning | Number of Input Points(pcs.) | 1 | Case color | Black |
---|---|---|---|---|---|
Auxiliary output points | 2 |
Please check the type/dimensions/specifications of the part E5AN-HAA2HHBF AC100-240 in the Thermac NEO Temperature Controller (Digital Control Meter) [E5□N/E5□N-H/E5□N-HT] series.
Part Number |
---|
E5AN-HAA2HB AC100-240 |
E5AN-HAA2HHBB AC100-240 |
E5AN-HPRR2BB AC100-240 |
E5AN-HTAA2HB AC100-240 |
E5AN-HTAA2HHBB AC100-240 |
E5AN-HTAA2HHBF AC100-240 |
Part Number | Price | Minimum Order Qty | Volume Discount | Days to Ship | Input Method | Output Type | Number of Control Points | Setting Method | Failure Detecting Function | Power Supply Voltage (V) | Control Output 1 | Control Output 2 | Event Input (Point) | Heater burnout / SSR failure / heater overcurrent detection function | Program type | Specifications | Communication | Transmission Output |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
฿ 16,400.00 | 1 Piece(s) | 5 Day(s) | Platinum temperature measuring resistor / Thermocouple | - | - | - | Heater Over current / SSR Breakdown / Heater Breakage | 100 to 240 VAC | Output Unit Method | Output Unit Method | 2 | Detection for single-phase heater | - | - | - | - | ||
฿ 19,601.00 | 1 Piece(s) | 5 Day(s) | Platinum temperature measuring resistor / Thermocouple | - | - | - | Heater Over current / SSR Breakdown / Heater Breakage | 100 to 240 VAC | Output Unit Method | Output Unit Method | 4 | Detection for single or three-phase heater | - | - | - | - | ||
฿ 21,930.00 | 1 Piece(s) | 5 Day(s) | Platinum temperature measuring resistor / Thermocouple | - | - | - | - | 100 to 240 VAC | Relay Output for Position Proportional | Relay Output for Position Proportional | - | - | - | - | - | - | ||
฿ 16,400.00 | 1 Piece(s) | 5 Day(s) | Voltage / Current / Platinum temperature measuring resistor / Thermocouple | - | - | - | Heater Over current / SSR Breakdown / Heater Breakage | 100 to 240 VAC | Output Unit Method | Output Unit Method | 2 | Detection for single-phase heater | Black type, three-stage display | - | - | - | ||
฿ 19,601.00 | 1 Piece(s) | 5 Day(s) | Voltage / Current / Platinum temperature measuring resistor / Thermocouple | Current / Linear Voltage / SSR Drive Output Voltage / Relay contact | 2 | RSP Input / Key input | Heater Over current / SSR Breakdown / Heater Breakage | 100 to 240 VAC | Output Unit System | Output Unit System | 4 | Detection for single or three-phase heater | - | 96×96 mm program type | None | None | ||
฿ 20,765.00 | 1 Piece(s) | 6 Day(s) | Voltage / Current / Platinum temperature measuring resistor / Thermocouple | Current / Linear Voltage / SSR Drive Output Voltage / Relay contact | 2 | RSP Input / Key input | Heater Over current / SSR Breakdown / Heater Breakage | 100 to 240 VAC | Output Unit System | Output Unit System | 2 | Detection for single or three-phase heater | - | 96×96 mm program type | None | 1 |
How can we improve?