Non-Contact Temperature Sensor [ES1]

Brand :
OMRON

Caution

    Product Description

    [ES1-N]
    Measures temperature without touching the workpiece. Provides hygienic and more efficient temperature management without damages.
    [ES1B]
    Provides low cost, non-contact temperature measurement.
    [ES1C]
    Provides a wide measurement range of 0 to 400°C and an excellent environmental resistance.

    Dimensional Drawing of OMRON Other Temperature / Humidity Sensors

    Model ES1-LP3-N/Model ES1-LP10-N Main Unit of OMRON Other Temperature / Humidity Sensors

    Non-contact temperature sensor ES1 Model ES1-LP3-N/Model ES1-LP10-N Body outline drawing

    Model ES1-LW50-N/Model ES1-LW50L-N Main Unit of OMRON Other Temperature / Humidity Sensors

    Non-contact temperature sensor ES1 Model ES1-LW50-N/Model ES1-LW50L-N Body outline drawing

    (The ES1-LW50-N does not have the laser output port (6) or laser switch (7).)

    Model ES1-LW100-N/Model ES1-LW100L-N Main Unit of OMRON Other Temperature / Humidity Sensors

    Non-contact temperature sensor ES1 Model ES1-LW100-N/Model ES1-LW100L-N Body outline drawing

    (The ES1-LW100-N does not have the laser output port (6) or laser switch (7).)

    Model ES1B of OMRON Other Temperature / Humidity Sensors

    Non-contact temperature sensor ES1 Model ES1B outline drawing

    Model ES1C of OMRON Other Temperature / Humidity Sensors

    Non-contact temperature sensor ES1 Model ES1C outline drawing

    Specification Table of OMRON Other Temperature / Humidity Sensors

    ES1-N Ratings/Performance of OMRON Other Temperature / Humidity Sensors

    ES1-N

    typeNo aiming laserWith aiming laser
    Model numberModel ES1-LP3-NModel ES1-LP10-NModel ES1-LW50-NModel ES1-LW100-NModel ES1-LW50L-NModel ES1-LW100L-N
    Detector elementThermopile
    lenssilicon
    Wavelength8–14 μm
    outputUSB OutputResolution: 0.1°C
    Current Output4~20mA/-50~500℃*1
    Load impedance 250Ω or less
    Resolution 0.24μA
    4~20mA/-50~1,000℃*1
    Load impedance 250Ω or less
    Resolution 0.24μA
    4~20mA/-50~500℃*1
    Load impedance 250Ω or less
    Resolution 0.24μA
    4~20mA/-50~1,000℃ *1
    Load impedance 250Ω or less
    Resolution 0.24μA
    Power supply voltageDC12 to 24V/USB bus power (USB bus power only, other than current output possible)
    Allowable power supply voltage fluctuation95 to 105% of power supply voltage
    Current consumption30mA or less (24V DC)・30mA or less (DC24V, when aiming laser is not used)
    ・40mA or less (DC24V, when aiming laser is used)
    Cable length2m±5cm
    Measurement accuracyUSB output
    : Within ±(-8%rdg+1)℃
    (measurement temperature: -50 to 0℃)
    Within ±1℃
    (measurement temperature: 0 to 200℃)
    Within ±0.5%rdg℃
    (200 to 500℃)
    Current output
    : Difference from USB output is
    within (±0.1% output range)℃
    USB output
    : Within ±(-8%rdg+1)℃
    (measurement temperature: -50 to 0℃)
    Within ±1℃
    (measurement temperature: 0 to 200℃)
    Within ±0.5%rdg℃
    (200 to 1,000℃)
    Current output
    : Difference from USB output is
    within (±0.1% output range)℃
    USB output
    : Within ±(-8%rdg+1)℃
    (measurement temperature: -50 to 0℃)
    Within ±1℃
    (measurement temperature: 0 to 200℃)
    Within ±0.5%rdg℃
    (200 to 500℃)
    Current output
    : Difference from USB output is
    within (±0.1% output range)℃
    USB output
    : Within ±(-8%rdg+1)℃
    (measurement temperature: -50 to 0℃)
    Within ±1℃
    (measurement temperature: 0 to 200℃)
    Within ±0.5%rdg℃
    (200 to 1,000℃)
    Current output
    : Difference from USB output is
    within (±0.1% output range)℃
    Reproducibility・Within 0.5℃・Within 1℃
    (measurement temperature: -50 to 0℃)
    ・Within 0.5℃
    (measurement temperature: 0 to 500℃)
    ・Within 1℃
    (measurement temperature: 500 to 1,000℃)
    ・Within 0.5℃・Within 1℃
    (measurement temperature: -50 to 0℃)
    ・Within 0.5℃
    (measurement temperature: 0 to 500℃)
    ・Within 1℃
    (measurement temperature: 500 to 1,000℃)
    Temperature Drift・Within ±0.5℃/℃
    (measurement temperature: -50 to 0℃)
    ・Within ±0.25℃/℃
    (measurement temperature: 0 to 500℃)
    ・Within ±0.5℃/℃
    (measurement temperature: -50 to 0℃)
    ・Within ±0.25℃/℃
    (measurement temperature: 0 to 500℃)
    ・Within ±0.5℃/℃
    (measurement temperature: 500 to 1,000℃)
    ・Within ±0.5℃/℃
    (measurement temperature: -50 to 0℃)
    ・Within ±0.25℃/℃
    (measurement temperature: 0 to 500℃)
    ・Within ±0.5℃/℃
    (measurement temperature: -50 to 0℃)
    ・Within ±0.25℃/℃
    (measurement temperature: 0 to 500℃)
    ・Within ±0.5℃/℃
    (measurement temperature: 500 to 1,000℃)
    Effects of electromagnetic interference *2Electromagnetic field discharge
    immunity
    Within ±10℃ (80MHz to 1.0GHz)
    Conducted interference
    immunity
    Within ±10℃ (150kHz to 80MHz)
    Response TimeCurrent output: 0.14 s or less (95% response, moving average 1)
    EmissivityFactory setting: 0.95 Can be changed from 0.100 to 1.999 using the setting tool
    Moving average functionFactory setting: 10
    Can be changed from 1 to 1,000 using the setting tool
    Factory setting: 50 Can be changed from 1 to 1,000
    using the setting tool
    Factory setting: 10 Can be changed from 1 to 1,000
    using the setting tool
    Factory setting: 50 Can be changed from 1 to 1,000
    using the setting tool
    Operating temperature and humidity rangeTemperature: 0 to 55°C, Humidity: 35 to 85% (no condensation)
    Storage Temperature Range-20 to 55°C (no condensation)
    Vibration resistancemalfunction10~55Hz 20m/s2 3 axis direction 10min
    Durability10 to 55Hz, half amplitude 0.75mm, 3 axial directions 2h
    Protective structureNo
    Compliance standardsCE, KC, FCC, RCM
    -IEC60825-1, PSC, FDA
    External dimensionsW32mm×H40mm×L58mmW32mm×H40mm×L90.3mmW32mm×H40mm×L60.4mmW32mm×H40mm×L92.7mm
    massApprox. 95gApprox. 115gApprox. 95gApprox. 115g
    Standard accessoriesInstruction manual, mounting bracket,
    power/output cable (2m),
    installation gauge
    Instruction manual, mounting bracket, power/output cable (2m)

    *1. The default range is 0 to +500°C. When using in -50°C to +500°C or -50°C to +1,000°C, the range must be changed using the ES1-TOOLS.
    *2. Industrial electromagnetic environment (EN/IEC 61326-1 Table 2). In this case, the measurement error is ±10°C.

    Model ES1B

    itemModel number
    Model ES1B
    Power supply voltageDC12/24V
    Allowable power supply voltage fluctuation90% to 110% of power supply voltage
    Current consumption20mA or less
    Measurement Temperature Range10~70℃, 60~120℃, 115~165℃, 140~260℃
    Accuracy*1±5℃*2±2%PV or ±2℃, whichever is greater
    ±10℃*2±4%PV or ±4℃, whichever is greater
    ±30℃*2±6%PV or ±6℃, whichever is greater
    ±40℃*2±8%PV or ±8℃, whichever is greater
    Reproducibility±1%PV or ±1℃, whichever is greater
    Temperature Drift±0.4℃/℃ or less
    Effects of electromagnetic interferenceField Strength ImmunityWithin ±10℃ (80-800MHz)
    Within ±30℃ (800-1000MHz)
    Conducted interference immunity±10℃
    Measurement distance: Field of view diameter1:1 typ.
    Wavelength6.5 to 14.0 μm
    Light receiving elementThermopile
    Response speedApproximately 300 ms at 63% response
    Output Impedance1 to 4 kΩ
    Operating Temperature Range-25 to +70°C (no condensation or freezing)
    Permitted ambient humidityRelative humidity 35-85%
    Vibration resistance (durability)98m/s2 10~55Hz 2h each in X, Y, and Z directions
    Impact resistance (durability)300m/s2 3 times each in X, Y, and Z directions
    Body MaterialABS resin
    Protective structureIP65
    Compliance standardsCE marking*3
    massApprox. 120g
    Lead WireCompensating wire 3m
    PVC coating, heat resistant up to 70℃

    *1.For K thermocouple characteristics and emissivity of 0.98
    *2.Example of temperature change from any reference temperature of the measurement object
        : When corrected to a reference temperature of 50°C,         the accuracy is
            the greater of ±2% PV or ±2°C at 55°C, and ±4% PV or ±4°C at 60°C.*3.EN61326-1: Industrial electromagnetic environment (EN/IEC61326-1 Table 2)

    ES1C

    itemModel number
    Model ES1C
    Power supply voltageDC12-24V
    Allowable voltage fluctuation range90 to 110% of rated voltage
    Current consumption70mA or less
    Measurement Temperature Range0~400℃
    Measurement accuracy0 to 200℃: ±2℃ 201 to 400℃: ±1% PV (emissivity 0.95)
    Effects of electromagnetic interferenceField Strength Immunity±10℃ max
    Conducted interference immunity±10℃ max
    Response Time100ms/90%
    Reproducibility±1% of reading
    Wavelength8–14 μm
    Light receiving elementThermopile
    EmissivityFixed at 0.95
    Current OutputDC4 to 20mA Load 250Ω or less
    Ambient Temperature RangeDuring use: 0 to +70°C During storage: -20 to +70°C (no freezing or condensation)
    Ambient Humidity RangeUse/storage: Relative humidity 35-85%
    Vibration resistance (durability)10~55Hz, amplitude 1.5mm, 2h each in X, Y, and Z directions
    mass180g
    Protective structureIP67 equivalent
    Compliance standardsCE marking*

    *EN61326-1: Industrial electromagnetic environment (EN/IEC61326-1 Table 2)

    Bill of Materials of OMRON Other Temperature / Humidity Sensors

    No.name
    (1)lens
    (2)Mounting bracket screw holes
    (3)Tripod screw hole
    (4)Power output connector
    (5)Micro USB Connector
    (6)Laser output port
    (7)Laser Switch
    (8)Installation gauge fixing hole
    Viewed Products
    Recently Viewed Products
    My Components
    My Components
    0
    Cart
    Cart
    Economy Series
    MRO Product

    Chat with MISUMI

    Chat service is available for any inquiry to MISUMI

    Service hours

    9:00 - 18:00 (Mon-Sat)

    For out of service hours, you can leave a message to us.
    We will reply to your inquiries on the next business day.
    (except Sundays and public holidays).

    Noted for use

    Chat service is for Corporate customers and limited for Thai language.

    Request for Quotation and Place Order is not available on Chat.

    Start chat