Small Limit Switch [D4C]

Caution
Product Description
Compact limit switch excelling in compact size, thin and high seal properties.
[Features]
· Approved by EN (TÜV), UL, CSA, CCC standard. (ask your manufacturer for information on approved models)
· High sealing property compliant with IEC Standard IP67.
· The plunger has a seal packing, a diaphragm and the built-in switch has a protective cap and a triple seal structure.
· 3 m and 5 m cords are used as a standard. Series with cords certified by UL and CSA standards.
· Plunger type enables multiple mountings.
· A series of LED indicator lights (red) is made to facilitate confirmation during operation. (Lights up when not operating as a standard)
· VCTF oil-resistant cord type and pre-wired type products confirm with CE marking. (However this is applicable to the Standard type only)
Dimensional Drawing of OMRON Limit Switch
Model D4C-□□01 of Limit Switch

*For information on model numbers other than those listed above, please refer to the digital catalog.
Specification Table of OMRON Limit Switch
Performance of Limit Switch
| Protective structure of Limit Switch | IP67 | |
|---|---|---|
| Durability*1 | Mechanical*3 | Over 10 million times |
| Electrical*2 | 200,000 times or more (AC125V 5A resistive load) | |
| Allowable Operating Speed | 0.1mm to 0.5m/s (for plunger type) 1mm to 1m/s (for roller lever type) | |
| Allowable operating frequency | Mechanical | 120 times/min |
| Electrical | 30 times/min | |
| Rated Frequency | 50/60Hz | |
| Insulation resistance | 100MΩ or more (at DC500V mega) | |
| Contact resistance (initial value) | 250mΩ or less (with 2m cord) 300mΩ or less (with 3m cord) 400mΩ or less (with 5m cord) | |
| Withstand voltage | Between same-polarity terminals | AC1,000V 50/60Hz 1min |
| Between live metal parts and earth | AC1,500V 50/60Hz 1min Uimp 2.5kV (EN60947-5-1) | |
| Between each terminal and non-current-carrying metal parts | AC1,500V 50/60Hz 1min Uimp 2.5kV (EN60947-5-1) | |
| Rated insulation voltage (Ui) | 300V (EN60947-5-1) *5 | |
| Pollution level (usage environment) | 3 (EN60947-5-1) | |
| Short Circuit Protection Device | 10A fuse type gI or gG (IEC60269) | |
| Conditional Short Circuit Current | 100A (EN60947-5-1) | |
| Rated sealed thermal current (I the) | 5A, 4A, 0.5A (EN60947-5-1) | |
| Electric shock protection class | Class I (with earth wire)*6 | |
| vibration | malfunction | 10 to 55Hz, double amplitude 1.5mm *4 |
| Shock Resistant | Durability | Up to 1,000m/s2 |
| malfunction | Maximum 500m/s2* 4 | |
| Ambient temperature | -10 to +70℃ (but do not freeze) | |
| Ambient humidity | 35~95% RH | |
| Mass (for D4C-1202) | Approx. 360g (with VCTF3m) approx. 540g (with VCTF5m) | |
Note: The above values are initial values of Limit Switch.
*1. The durability values are for an ambient temperature of 5 to 35°C and an ambient humidity of 40 to 70% RH, but the durability varies depending on the type of load and the magnitude of the current.
*2. Pre-wired type: 1 million operations or more. (DC specification, switching current 0.1A)
*3. Weather-resistant type: 500,000 operations or more.
*4. Plastic rod type excluded.
*5. Pre-wired type: 250V.
*6. Pre-wired type: class III
Structure of Limit Switch