J4/J3/JN Series Mitsubishi Electric Cable for Encoder

Caution
Product Description
An easy-to-remove relay type is being added one by one! Encoder cable with a specified length (0.2 to 50 m)! Opposite load side type or angle that pulls out the cable on the opposite side of the motor rotation axis, which is not available in the optional cable Types are also available. Fixed or movable cables can be selected.
● A new angle model now available!
● Select from fixed cables and movable cables.
● Non-load-side model (cable extracted on the other side of motor rotation axis) also available.
· The parts used are the recommended parts listed in the "Mitsubishi Electric Corporation: MR-J3-□A Servo Amplifier Technical Data." (Some equivalent products used)
· If you need 10 m or more, select a long distance model.
· Long distance model cable length goes up to 50 m.
·*1 Cables marked *2 are fitted with a relay connector and are not a one-end cut off model. Use this model with 2 cables as a set.
Wiring and Wire Color Page
>>Click here.
Component Page
>>Click here.
Specifications


Cable for Connections (Dual-end processed type). In case you need a cable over 10m long, use "Long Distance Type" cables.
Load Side Leading...Motor Shaft Side Cable Leading, Anti-Load Side Leading...Anti-Motor Shaft Side Cable Leading
* Cable length specifiable by 0.1 m increments
| Compatible Amplifier | Compatible Motor | Outline Image | Model Number | Cable Type | |
| MR-J4-□ MR-J3-□ MR-JN□ Standard Type (Up to 10 m) | HG-KR□ HG-MR□ HF-KP□ HF-MP□ HF-KN□ | (1) For Direct Connection | Dual End (Load Side Leading) | SVEM-J3HF1 | A (For Fixed) 0.2 ~ 10 m B (For Movable) 0.2 ~ 10 m |
| Dual End (Anti-Load Side Leading) | SVEM-J3HF1R | ||||
| HF-SP□ HC-LP□ HC-RP□ HC-UP□ HA-LP□ HF-JP□HG-SR□ HG-RR HG-UR HG-JR53 (4), 73 (4), 103 (4), 153 (4), 203 (4), 353 (4), 503 (4), 703 (4), 903 (4) | (2) For Direct Connection | Double-ended | SVEM-J3HF2 | ||
| MR-J4-□ MR-J3-□ MR-JN□ Long Distance Type (Up to 50 m) | HG-KR□ HG-MR□ HF-KP□ HF-MP□ HF-KN□ | (3) Amplifier Side Relay *1 (* Use with 2 as a set) | Dual End: 1 ~ 20 m | SVEM-J3HF1L-C20 | C (for fixed) 1 ~ 20m |
| Dual End: 20 ~ 30m | SVEM-J3HF1L-C30 | C (for fixed) 20 ~ 30m | |||
| Dual End: 1 ~ 20 m | SVEM-J3HF1L-D20 | D(for movable) 1 ~ 20 m | |||
| Dual End: 20 ~ 50 m | SVEM-J3HF1L-D50 | D(for movable) 20 ~ 50m | |||
| (4) Motor Side Relay *2 (* Use with 1 as a set) | Two Ends (Load Side) | SVEM-J3HF1M | A (for fixed) 0.2 ~ 0.3 m B (for movable) 0.2 ~ 10 m | ||
| Both Ends (Anti-Load Side) | SVEM-J3HF1RM | ||||
| HF-SP□ HC-LP□ HC-RP□ HC-UP□ HA-LP□ HF-JP□HG-SR□ HG-RR HG-UR HG-JR53 (4), 73 (4), 103 (4), 153 (4), 203 (4), 353 (4), 503 (4), 703 (4), 903 (4) | (2) For Direct Connection | Double-ended | SVEM-J3HF2L | C (for fixed) 10 ~ 30 m D (for movable) 10 ~ 50m | |

Load Side Leading...Motor Shaft Side Cable Leading, Anti-Load Side Leading...Anti-Motor Shaft Side Cable Leading
* Cable length specifiable by 0.1 m increments
| Compatible Amplifier | Compatible Motor | Outline Image | Model Number | Cable Type | |
| MR-J4-□ MR-J3-□ MR-JN□ Standard Type (Up to 10 m) | HG-KR□ HG-MR□ HF-KP□ HF-MP□ HF-KN□ | (5) Amplifier Side, One-End | Cut off | SVEM-J3HF1-HA | ![]() |
| Motor Side Connector Set (Load Side) | SVEM-J3HF1-HASET | ||||
| (6) Motor Side, One-End (Load Side Leading) | Cut off | SVEM-J3HF1-HM | |||
| Amplifier Side Connector Set | SVEM-J3HF1-HMSET | ||||
| (6) Motor Side, One-End (Anti-Load Side Leading) | Cut off | SVEM-J3HF1R-HM | |||
| Amplifier Side Connector Set | SVEM-J3HF1R-HMSET | ||||
| HF-SP□ HC-LP□ HC-RP□ HC-UP□ HA-LP□ HF-JP□ HG-SR□ HG-RR HG-UR HG-JR53 (4), 73 (4), 103 (4), 153 (4), 203 (4), 353 (4), 503 (4), 703 (4), 903 (4) | (8) Amplifier Side, One-End | Cut off | SVEM-J3HF2-HA | ||
| Motor Side Connector Set | SVEM-J3HF2-HASET | ||||
| (9) Motor Side, One-End | Cut off | SVEM-J3HF2-HM | |||
| Amplifier Side Connector Set | SVEM-J3HF2-HMSET | ||||
| MR-J4-□ MR-J3-□ MR-JN□ Long Distance Type (Up to 50 m) | HG-KR□ HG-MR□ HF-KP□ HF-MP□ HF-KN□ | (7) Amplifier Side Relay *1 (* Use with 2 as a set) | One End + Connector for Relay 10 ~ 20 m | SVEM-J3HF1L-HASET-C20 | C (for fixed) 10 ~ 20m |
| One End + Connector for Relay: 20 ~ 30 m | SVEM-J3HF1L-HASET-C30 | C (for fixed) 20 ~ 30m | |||
| One End + Connector for Relay 10 ~ 20 m | SVEM-J3HF1L-HASET-D20 | D(for movable) 10 ~ 20 m | |||
| One End + Connector for Relay: 20 - 50 m | SVEM-J3HF1L-HASET-D50 | D(for movable) 20 ~ 50m | |||
| HF-SP□ HC-LP□ HC-RP□ HC-UP□ HA-LP□ HF-JP□ HG-SR□ HG-RR HG-UR HG-JR53 (4), 73 (4), 103 (4), 153 (4), 203 (4), 353 (4), 503 (4), 703 (4), 903 (4) | (8) Amplifier Side, One-End | Cut off | SVEM-J3HF2L-HA | C (For Fixed) 10 ~ 30m D (For Movable) 10 ~ 50m | |
| Motor Side Connector Set | SVEM-J3HF2L-HASET | ||||
| (9) Motor Side, One-End | Cut off | SVEM-J3HF2L-HM | |||
| Amplifier Side Connector Set | SVEM-J3HF2L-HMSET | ||||

| Compatible Amplifier | Compatible Motor | Outline Image | Model Number | Cable Type | |
| MR-J3-□ Standard Type (Up to 10 m) | HF-SP□ HC-LP□ HC-RP□ HC-UP□ HA-LP□ HF-JP□ | (10) For Direct Coupling | Double-ended | SVEM-J3HF2AL | ![]() |
| (11) Amplifier Side, One-End | Motor Side Cut Off | SVEM-J3HF2AL-HA | |||
| Motor Side Connector Set | SVEM-J3HF2AL-HASET | ||||
| (12) Motor Side, One-End | Amplifier Side Cut Off | SVEM-J3HF2AL-HM | |||
| Amplifier Side Connector Set | SVEM-J3HF2AL-HMSET | ||||
| (10) For Direct Connection | Double-ended | SVEM-J3HF2LAL | ![]() | ||
| (11) Amplifier Side, One-End | Motor Side Cut Off | SVEM-J3HF2LAL-HA | |||
| Motor Side Connector Set | SVEM-J3HF2LAL-HASET | ||||
| (12) Motor Side, One-End | Amplifier Side Cut Off | SVEM-J3HF2LAL-HM | |||
| Amplifier Side Connector Set | SVEM-J3HF2LAL-HMSET | ||||