Dual Axis Motorized Goniometer Stages, Positioning Repeatability ±0.01°

Caution
- Download Free! >> Economy Series Catalog (TH-EN-FY25) CLICK here
Product Description
2-Axis Motorized Goniometer Stages are an economy item, The price is cheaper than the MISUMI standard product.They offer a wide variety of sizes to choose from.
[Feature]
● Feed Screw : Ball Screw Φ6
● Table Size Width X Length (mm.) : 60 x 60
● Operating Temperature (℃) : 10 to 50 (without condensation)
● Material and Surface Treatment : Aluminum Alloy Black Anodized
[Application]
2-Axis Motorized Goniometer Stages are commonly used in various applications in factory automation systems
Product Overview
Dimensional Drawing

Material: Aluminum Alloy
Surface Treatment: Black Anodized | Part Number | SensorPosition | Driver | Cable | Mechanical Specification | Accuracy Specification | |||||||
Type | No. | Stage Surface (mm) | Travel Distance (°) Upper/Lower Axis | Load Capacity (N) | Height of Rotation Center (mm) | Weight (kg) | Maximum Speed (°/sec) Upper/Lower Axis | One-Way Positioning Accuracy | Repetitive Positioning Accuracy | |||
| E-GMPWG | 60-50 | L (forward) R (reverse) | A | 2 (2m cable) 4 (4m cable) | 60×60 | ±9°/±5.5° | 49 | 50±0.2 | 1.0 | 10.5/7 | Within 0.08° | Within ±0.01° |
| 60-75 | ±5.5°/±5° | 75±0.2 | 7/5.5 | |||||||||
| 60-100 | ±5°/±4° | 100±0.2 | 5.5/4.5 | |||||||||
Driver: Driver model used in this series: E-DR42B.■ Universal Specifications
| No. | 60-50 | 60-75 | 60-100 | |
| Feed Screw | Ball Screw Φ6, Lead 1mm | |||
| Guide | Curved cross roller guide | |||
| Motor | Type | 2-Phase Stepper Motor 1.3A/Phase | ||
| Step Angle | 1.8° | |||
| Resolution (Pulse) Full | Upper axis | ≒0.0052° | ≒0.0036° | ≒0.0027° |
| Lower axis | ≒0.0036° | ≒0.0027° | ≒0.0022° | |
| Driver | Power Voltage | DC12~50V | ||
| Output Current | 0.1~2.2A | |||
| Pulse Signal Voltage | 5~24V | |||
| Subdivision | 200~51200 | |||
| Connector | Part Number | HR10A-10R-12P (HIROSE) | ||
| Receiving Side Part Number | HR10A-10P-12S (HIROSE) | |||
| Sensor Substrate | Limit Sensor | Provided | ||
| Origin Sensor | Provided | |||
| Power Voltage | DC24V±10% | |||
| Sensor Type | Photomicro Sensor EE-SX4320 (OMRON) | |||
| Control Output | NPN Open Collector Output | |||
| Output Logic | When detecting (shading): output transistor OFF (non-conductive) | |||


■Timing Diagram

t1<0.1 us t2≥0.9 us t3≥10 us
t4: ENA (Enable Signal) t4 should be at least 10 μs ahead of DIR, and it is determined as high. Generally, ENA+ and ENA- are recommended to be suspended.
Product Features
Usage Method of Goniometer

Precautions
Application Industries
| Electronics/Home Appliance | Automotive | Medical | ||
![]() | ![]() | ![]() | ||
| Smart phone | Semiconductor | Lithium battery | ||
![]() | ![]() | ![]() |
Related Products
| Economy series X-Axis Motorized Positioning Stages | Economy series XY-Axis Motorized Positioning Stages | Economy series Z-Axis Motorized Positioning Stages |
![]() | ![]() | ![]() |
| Representative model: C-XMBS420-L-A-2 | Representative model: C-XYMBS420-L-A-2 | Representative model: C-ZMBS420-L-A-2 |
Related Documents of Goniometer
Compatible drivers support dual-pulse and pulse + direction control. For installation dimensions and user manual, please refer to: E-DR42B.
Sensor
Driver
Cable
Type
No.