1. No. of part number of this product, can see and select from the list here
2. Or select spec by configure tab until part number generated
3. Product information available in this area

(!) Since support from Microsoft will end on January 14 2020, Windows 7 user might not be able to use MISUMI website effectively. Please consider to update your system as ‘MISUMI Website system requirement’.

    Sales
  • Viewed
    Products
  • My
    Components
  • Cart
Recently Viewed Products
X
My Components
X
Cart Item(s)
X
Loading...
  • แจ้งวันหยุดทำการในเดือน มิถุนายน 2567 | Notice holiday in June 2024 > คลิก

High Temperature Insulation Sheets

High Temperature Insulation Sheets
You can add up to 6 items per a category to the compare list.

Part Number :
  • Price :
    ---
  • Qty :
  • Days to Ship :
    ---
  • Total Price :
    ---

Select part number to Order Now/ Add to Cart

Product Description

High Temperature Insulation Sheets
Heat insulating plates are used for various purposes to manage and control heat transfer in different applications. They offer a wide variety of sizes to choose from.
[Feature]
● Shape : Circular Type
● Plate Thickness (mm.): 3, 5, 10 and 15
● Operating Environment Temperature (℃) : Room Temp. ~ 180, Room Temp. ~ 220, Room Temp. ~ 400 and Room Temp. ~ 500
● Plate Type : Standard (No holes)/ Plate with Holes (2/3/4 holes)
[Application]
It is used for thermal insulation of connecting parts and thermal insulation of flanges

 

Part Number 

  • Incomplete part number.
    Please use left hand selections to complete a part number.
Loading...
Part Number
ENJHP2H5-[50-400/1]-[0-50/1]-[20-390/1]-M[3,​4]
ENJHP2H5-[50-400/1]-[0-50/1]-[20-390/1]-N[3,​4,​5,​6,​8,​10]
ENJHP2H5-[50-400/1]-[0-50/1]-[20-390/1]-P[3,​4,​5,​6]
ENJHP2H10-[50-400/1]-[0-50/1]-[20-390/1]-M[3,​4,​5,​6]
ENJHP2H10-[50-400/1]-[0-50/1]-[20-390/1]-N[3,​4,​5,​6,​8,​10]
ENJHP2H10-[50-400/1]-[0-50/1]-[20-390/1]-Z[4,​5,​6]
ENJHP2H10-[50-400/1]-[0-50/1]-[20-390/1]-Z*[4,​5,​6]
ENJHP2H15-[50-400/1]-[0-50/1]-[20-390/1]-M[3,​4,​5,​6,​8]
ENJHP2H15-[50-400/1]-[0-50/1]-[20-390/1]-N[3,​4,​5,​6,​8,​10]
ENJHP2H15-[50-400/1]-[0-50/1]-[20-390/1]-Z[4,​5,​6,​8]
ENJHP2H15-[50-400/1]-[0-50/1]-[20-390/1]-Z*[4,​5,​6,​8]
ENJHP3H5-[50-400/1]-[0-50/1]-[20-390/1]-M[3,​4]
ENJHP3H5-[50-400/1]-[0-50/1]-[20-390/1]-N[3,​4,​5,​6,​8,​10]
ENJHP3H5-[50-400/1]-[0-50/1]-[20-390/1]-P[3,​4,​5,​6]
ENJHP3H10-[50-400/1]-[0-50/1]-[20-390/1]-M[3,​4,​5,​6]
ENJHP3H10-[50-400/1]-[0-50/1]-[20-390/1]-N[3,​4,​5,​6,​8,​10]
ENJHP3H10-[50-400/1]-[0-50/1]-[20-390/1]-Z[4,​5,​6]
ENJHP3H10-[50-400/1]-[0-50/1]-[20-390/1]-Z*[4,​5,​6]
ENJHP3H15-[50-400/1]-[0-50/1]-[20-390/1]-M[3,​4,​5,​6,​8]
ENJHP3H15-[50-400/1]-[0-50/1]-[20-390/1]-N[3,​4,​5,​6,​8,​10]
ENJHP3H15-[50-400/1]-[0-50/1]-[20-390/1]-Z[4,​5,​6,​8]
ENJHP3H15-[50-400/1]-[0-50/1]-[20-390/1]-Z*[4,​5,​6,​8]
ENJHP4H5-[50-400/1]-[0-50/1]-[20-390/1]-M[3,​4]
ENJHP4H5-[50-400/1]-[0-50/1]-[20-390/1]-N[3,​4,​5,​6,​8,​10]
ENJHP4H5-[50-400/1]-[0-50/1]-[20-390/1]-P[3,​4,​5,​6]
ENJHP4H10-[50-400/1]-[0-50/1]-[20-390/1]-M[3,​4,​5,​6]
ENJHP4H10-[50-400/1]-[0-50/1]-[20-390/1]-N[3,​4,​5,​6,​8,​10]
ENJHP4H10-[50-400/1]-[0-50/1]-[20-390/1]-Z[4,​5,​6,​8]
ENJHP4H10-[50-400/1]-[0-50/1]-[20-390/1]-Z*[4,​5,​6,​8]
ENJHP4H15-[50-400/1]-[0-50/1]-[20-390/1]-M[3,​4,​5,​6,​8]
ENJHP4H15-[50-400/1]-[0-50/1]-[20-390/1]-N[3,​4,​5,​6,​8,​10]
ENJHP4H15-[50-400/1]-[0-50/1]-[20-390/1]-Z[4,​5,​6,​8]
ENJHP4H15-[50-400/1]-[0-50/1]-[20-390/1]-Z*[4,​5,​6,​8]
ENJHP5-[50-400/1]-[0-50/1]
ENJHP10-[50-400/1]-[0-50/1]
ENJHP15-[50-400/1]-[0-50/1]
Part NumberPriceNameMinimum Order Qty.Volume DiscountDays to ShipRoHSRecommended Operating Temperature
(°C)
Plate Thickness T
(mm)
Application Type Counterbore Hole (Screw Nominal Dia.) [Z] D
(mm)
P.C.D
(mm)
Thread Insert (Screw Nominal Dia.) [M] Through Hole (Screw Nominal Dia.) [N] V
(mm)

-

GUIDE PLATE 1 Piece(s) 5 Day(s) 10Room Temp. ~ 2205Standard2H (Two Holes)-50 ~ 40020 ~ 3903 ~ 4-0 ~ 50

-

GUIDE PLATE 1 Piece(s) 5 Day(s) 10Room Temp. ~ 2205Standard2H (Two Holes)-50 ~ 40020 ~ 390-3 ~ 100 ~ 50

-

GUIDE PLATE 1 Piece(s) 5 Day(s) 10Room Temp. ~ 2205Standard2H (Two Holes)-50 ~ 40020 ~ 390--0 ~ 50

-

GUIDE PLATE 1 Piece(s) 5 Day(s) 10Room Temp. ~ 22010Standard2H (Two Holes)-50 ~ 40020 ~ 3903 ~ 6-0 ~ 50

-

GUIDE PLATE 1 Piece(s) 5 Day(s) 10Room Temp. ~ 22010Standard2H (Two Holes)-50 ~ 40020 ~ 390-3 ~ 100 ~ 50

-

GUIDE PLATE 1 Piece(s) 5 Day(s) 10Room Temp. ~ 22010Standard2H (Two Holes)4 ~ 650 ~ 40020 ~ 390--0 ~ 50

-

GUIDE PLATE 1 Piece(s) 5 Day(s) 10Room Temp. ~ 22010Standard2H (Two Holes)4 ~ 650 ~ 40020 ~ 390--0 ~ 50

-

GUIDE PLATE 1 Piece(s) 5 Day(s) 10Room Temp. ~ 22015Standard2H (Two Holes)-50 ~ 40020 ~ 3903 ~ 8-0 ~ 50

-

GUIDE PLATE 1 Piece(s) 5 Day(s) 10Room Temp. ~ 22015Standard2H (Two Holes)-50 ~ 40020 ~ 390-3 ~ 100 ~ 50

-

GUIDE PLATE 1 Piece(s) 5 Day(s) 10Room Temp. ~ 22015Standard2H (Two Holes)4 ~ 850 ~ 40020 ~ 390--0 ~ 50

-

GUIDE PLATE 1 Piece(s) 5 Day(s) 10Room Temp. ~ 22015Standard2H (Two Holes)4 ~ 850 ~ 40020 ~ 390--0 ~ 50

-

GUIDE PLATE 1 Piece(s) 5 Day(s) 10Room Temp. ~ 2205Standard3H (Three Holes)-50 ~ 40020 ~ 3903 ~ 4-0 ~ 50

-

GUIDE PLATE 1 Piece(s) 5 Day(s) 10Room Temp. ~ 2205Standard3H (Three Holes)-50 ~ 40020 ~ 390-3 ~ 100 ~ 50

-

GUIDE PLATE 1 Piece(s) 5 Day(s) 10Room Temp. ~ 2205Standard3H (Three Holes)-50 ~ 40020 ~ 390--0 ~ 50

-

GUIDE PLATE 1 Piece(s) 5 Day(s) 10Room Temp. ~ 22010Standard3H (Three Holes)-50 ~ 40020 ~ 3903 ~ 6-0 ~ 50

-

GUIDE PLATE 1 Piece(s) 5 Day(s) 10Room Temp. ~ 22010Standard3H (Three Holes)-50 ~ 40020 ~ 390-3 ~ 100 ~ 50

-

GUIDE PLATE 1 Piece(s) 5 Day(s) 10Room Temp. ~ 22010Standard3H (Three Holes)4 ~ 650 ~ 40020 ~ 390--0 ~ 50

-

GUIDE PLATE 1 Piece(s) 5 Day(s) 10Room Temp. ~ 22010Standard3H (Three Holes)4 ~ 650 ~ 40020 ~ 390--0 ~ 50

-

GUIDE PLATE 1 Piece(s) 5 Day(s) 10Room Temp. ~ 22015Standard3H (Three Holes)-50 ~ 40020 ~ 3903 ~ 8-0 ~ 50

-

GUIDE PLATE 1 Piece(s) 5 Day(s) 10Room Temp. ~ 22015Standard3H (Three Holes)-50 ~ 40020 ~ 390-3 ~ 100 ~ 50

-

GUIDE PLATE 1 Piece(s) 5 Day(s) 10Room Temp. ~ 22015Standard3H (Three Holes)4 ~ 850 ~ 40020 ~ 390--0 ~ 50

-

GUIDE PLATE 1 Piece(s) 5 Day(s) 10Room Temp. ~ 22015Standard3H (Three Holes)4 ~ 850 ~ 40020 ~ 390--0 ~ 50

-

GUIDE PLATE 1 Piece(s) 5 Day(s) 10Room Temp. ~ 2205Standard4H (Four Holes)-50 ~ 40020 ~ 3903 ~ 4-0 ~ 50

-

GUIDE PLATE 1 Piece(s) 5 Day(s) 10Room Temp. ~ 2205Standard4H (Four Holes)-50 ~ 40020 ~ 390-3 ~ 100 ~ 50

-

GUIDE PLATE 1 Piece(s) 5 Day(s) 10Room Temp. ~ 2205Standard4H (Four Holes)-50 ~ 40020 ~ 390--0 ~ 50

-

GUIDE PLATE 1 Piece(s) 5 Day(s) 10Room Temp. ~ 22010Standard4H (Four Holes)-50 ~ 40020 ~ 3903 ~ 6-0 ~ 50

-

GUIDE PLATE 1 Piece(s) 5 Day(s) 10Room Temp. ~ 22010Standard4H (Four Holes)-50 ~ 40020 ~ 390-3 ~ 100 ~ 50

-

GUIDE PLATE 1 Piece(s) 5 Day(s) 10Room Temp. ~ 22010Standard4H (Four Holes)4 ~ 850 ~ 40020 ~ 390--0 ~ 50

-

GUIDE PLATE 1 Piece(s) 5 Day(s) 10Room Temp. ~ 22010Standard4H (Four Holes)4 ~ 850 ~ 40020 ~ 390--0 ~ 50

-

GUIDE PLATE 1 Piece(s) 5 Day(s) 10Room Temp. ~ 22015Standard4H (Four Holes)-50 ~ 40020 ~ 3903 ~ 8-0 ~ 50

-

GUIDE PLATE 1 Piece(s) 5 Day(s) 10Room Temp. ~ 22015Standard4H (Four Holes)-50 ~ 40020 ~ 390-3 ~ 100 ~ 50

-

GUIDE PLATE 1 Piece(s) 5 Day(s) 10Room Temp. ~ 22015Standard4H (Four Holes)4 ~ 850 ~ 40020 ~ 390--0 ~ 50

-

GUIDE PLATE 1 Piece(s) 5 Day(s) 10Room Temp. ~ 22015Standard4H (Four Holes)4 ~ 850 ~ 40020 ~ 390--0 ~ 50

-

GUIDE PLATE 1 Piece(s) 5 Day(s) 10Room Temp. ~ 2205StandardStandard Type-50 ~ 400---0 ~ 50

-

GUIDE PLATE 1 Piece(s) 5 Day(s) 10Room Temp. ~ 22010StandardStandard Type-50 ~ 400---0 ~ 50

-

GUIDE PLATE 1 Piece(s) 5 Day(s) 10Room Temp. ~ 22015StandardStandard Type-50 ~ 400---0 ~ 50

Loading...

  1. 1

MISUMI Unit Example related to this product