• Scheduled Maintenance Notice: This site will be unavailable due to scheduled maintenance from 6:00 21/10 to 5:00 22/10/2018. We apologize for the inconvenience.
  • กรณีที่ไม่สามารถติดต่อเบอร์ 038-959200 รบกวนลูกค้าติดต่อที่เบอร์โทร.ชั่วคราว 033-010861-6 หรือ email cs@misumi.co.th ขออภัยในความไม่สะดวก
    If you cannot contact via 038-959200, Please contact temporary phone number 033-010861-6 or email cs@misumi.co.th, we apologize for any inconvenience.

NE-S, circuit breaker (generic form), S series, embedded shape, high capacity

Part Number

Configured Part Number is shown.

Part Number
NE102SAF2P60A
NE102SAF2P75A
NE102SAF2P100A
NE103SAF3P60A
NE103SAF3P75A
NE103SAF3P100A
NE104SAF4P60A
NE104SAF4P75A
NE104SAF4P100A
NE223SAF3P125A
NE223SAF3P150A
NE223SAF3P200A
NE223SAF3P225A
NE224SAF4P125A
NE224SAF4P150A
NE224SAF4P175A
NE224SAF4P225A
NE403SAF3P250A
NE403SAF3P300A
NE403SAF3P350A
NE403SAF3P400A
NE404SAF4P250A
NE404SAF4P300A
NE404SAF4P350A
NE404SAF4P400A
NE603SAF3P500A
NE603SAF3P600A
NE604SAF4P500A
NE604SAF4P600A
NE803SAF3P800A
Part NumberVolume DiscountDays to ShipAmpere frame Number of Poles Rated Current
(A)
Representative Standard Dimension height
(mm)
Dimension width
(mm)
Dimension depth
(mm)
Rated block capacity AC 690 V
(kA)
Rated block capacity AC 500 V
(kA)
Rated block capacity AC 440 V
(kA)
Rated block capacity AC 415 V
(kA)
Rated block capacity AC 380 V
(kA)
Rated block capacity AC 240 V
(kA)
Excess current tripping format Terminal structure Compatible Standards Standard accessories
9 Day(s) or more [100AF to 199AF] 100AF260PSE19212219462225303050Thermal - electromagnetFor crimp terminal M8JIS C 8201-2-1 Ann1·Ann2, IEC60947-2Terminal cover, terminal screw, mounting screw
9 Day(s) or more [100AF to 199AF] 100AF275PSE19212219462225303050Thermal - electromagnetFor crimp terminal M8JIS C 8201-2-1 Ann1·Ann2, IEC60947-2Terminal cover, terminal screw, mounting screw
9 Day(s) or more [100AF to 199AF] 100AF2100PSE19212219462225303050Thermal - electromagnetFor crimp terminal M8JIS C 8201-2-1 Ann1·Ann2, IEC60947-2Terminal cover, terminal screw, mounting screw
9 Day(s) or more [100AF to 199AF] 100AF360PSE19215719462225303050Thermal - electromagnetFor crimp terminal M8JIS C 8201-2-1 Ann1·Ann2, IEC60947-2Terminal cover, terminal screw, mounting screw
9 Day(s) or more [100AF to 199AF] 100AF375PSE19215719462225303050Thermal - electromagnetFor crimp terminal M8JIS C 8201-2-1 Ann1·Ann2, IEC60947-2Terminal cover, terminal screw, mounting screw
9 Day(s) or more [100AF to 199AF] 100AF3100PSE19215719462225303050Thermal - electromagnetFor crimp terminal M8JIS C 8201-2-1 Ann1·Ann2, IEC60947-2Terminal cover, terminal screw, mounting screw
19 Day(s) or more [100AF to 199AF] 100AF460PSE19219219462225303050Thermal - electromagnetFor crimp terminal M8JIS C 8201-2-1 Ann1·Ann2, IEC60947-2Terminal cover, terminal screw, mounting screw
19 Day(s) or more [100AF to 199AF] 100AF475PSE19219219462225303050Thermal - electromagnetFor crimp terminal M8JIS C 8201-2-1 Ann1·Ann2, IEC60947-2Terminal cover, terminal screw, mounting screw
19 Day(s) or more [100AF to 199AF] 100AF4100PSE19219219462225303050Thermal - electromagnetFor crimp terminal M8JIS C 8201-2-1 Ann1·Ann2, IEC60947-2Terminal cover, terminal screw, mounting screw
9 Day(s) or more [200AF to 399AF] 225AF3125-19215720242530404085Thermal - electromagnetFor crimp terminal M8JIS C 8201-2-1 Ann1·Ann2, IEC60947-2Terminal cover, terminal screw, mounting screw
9 Day(s) or more [200AF to 399AF] 225AF3150-19215720242530404085Thermal - electromagnetFor crimp terminal M8JIS C 8201-2-1 Ann1·Ann2, IEC60947-2Terminal cover, terminal screw, mounting screw
9 Day(s) or more [200AF to 399AF] 225AF3200-19215720242530404085Thermal - electromagnetFor crimp terminal M8JIS C 8201-2-1 Ann1·Ann2, IEC60947-2Terminal cover, terminal screw, mounting screw
9 Day(s) or more [200AF to 399AF] 225AF3225-19215720242530404085Thermal - electromagnetFor crimp terminal M8JIS C 8201-2-1 Ann1·Ann2, IEC60947-2Terminal cover, terminal screw, mounting screw
19 Day(s) or more [200AF to 399AF] 225AF4125-19219220242530404085Thermal - electromagnetFor crimp terminal M8JIS C 8201-2-1 Ann1·Ann2, IEC60947-2Terminal cover, terminal screw, mounting screw
19 Day(s) or more [200AF to 399AF] 225AF4150-19219220242530404085Thermal - electromagnetFor crimp terminal M8JIS C 8201-2-1 Ann1·Ann2, IEC60947-2Terminal cover, terminal screw, mounting screw
19 Day(s) or more [200AF to 399AF] 225AF4175-19219220242530404085Thermal - electromagnetFor crimp terminal M8JIS C 8201-2-1 Ann1·Ann2, IEC60947-2Terminal cover, terminal screw, mounting screw
19 Day(s) or more [200AF to 399AF] 225AF4225-19219220242530404085Thermal - electromagnetFor crimp terminal M8JIS C 8201-2-1 Ann1·Ann2, IEC60947-2Terminal cover, terminal screw, mounting screw
9 Day(s) or more [400AF or higher] 400AF3250-343223255203045505085Thermal - adjustable electromagnetBar terminal M12JIS C 8201-2-1 Ann1·Ann2, IEC60947-2Terminal cover, terminal screw, mounting screw
9 Day(s) or more [400AF or higher] 400AF3300-343223255203045505085Thermal - adjustable electromagnetBar terminal M12JIS C 8201-2-1 Ann1·Ann2, IEC60947-2Terminal cover, terminal screw, mounting screw
9 Day(s) or more [400AF or higher] 400AF3350-343223255203045505085Thermal - adjustable electromagnetBar terminal M12JIS C 8201-2-1 Ann1·Ann2, IEC60947-2Terminal cover, terminal screw, mounting screw
9 Day(s) or more [400AF or higher] 400AF3400-343223255203045505085Thermal - adjustable electromagnetBar terminal M12JIS C 8201-2-1 Ann1·Ann2, IEC60947-2Terminal cover, terminal screw, mounting screw
19 Day(s) or more [400AF or higher] 400AF4250-343268255203045505085Thermal - adjustable electromagnetBar terminal M12JIS C 8201-2-1 Ann1·Ann2, IEC60947-2Terminal cover, terminal screw, mounting screw
19 Day(s) or more [400AF or higher] 400AF4300-343268255203045505085Thermal - adjustable electromagnetBar terminal M12JIS C 8201-2-1 Ann1·Ann2, IEC60947-2Terminal cover, terminal screw, mounting screw
19 Day(s) or more [400AF or higher] 400AF4350-343268255203045505085Thermal - adjustable electromagnetBar terminal M12JIS C 8201-2-1 Ann1·Ann2, IEC60947-2Terminal cover, terminal screw, mounting screw
19 Day(s) or more [400AF or higher] 400AF4400-343268255203045505085Thermal - adjustable electromagnetBar terminal M12JIS C 8201-2-1 Ann1·Ann2, IEC60947-2Terminal cover, terminal screw, mounting screw
Quote [400AF or higher] 600AF3500-343268347.5203045505085Thermal - adjustable electromagnetBar terminal M12JIS C 8201-2-1 Ann1·Ann2, IEC60947-2Terminal cover, terminal screw, mounting screw, auxiliary handle
Quote [400AF or higher] 600AF3600-343268347.5203045505085Thermal - adjustable electromagnetBar terminal M12JIS C 8201-2-1 Ann1·Ann2, IEC60947-2Terminal cover, terminal screw, mounting screw, auxiliary handle
19 Day(s) or more [400AF or higher] 600AF4500-343338347.5203045505085Thermal - adjustable electromagnetBar terminal M12JIS C 8201-2-1 Ann1·Ann2, IEC60947-2Terminal cover, terminal screw, mounting screw, auxiliary handle
19 Day(s) or more [400AF or higher] 600AF4600-343338347.5203045505085Thermal - adjustable electromagnetBar terminal M12JIS C 8201-2-1 Ann1·Ann2, IEC60947-2Terminal cover, terminal screw, mounting screw, auxiliary handle
14 Day(s) or more [400AF or higher] 800AF3800-343268347.5203045505085Thermal - adjustable electromagnetBar terminal M12JIS C 8201-2-1 Ann1·Ann2, IEC60947-2Terminal cover, terminal screw, mounting screw, auxiliary handle

Loading...

  1. 1

Basic Information

Rated block capacity, voltages except VAC 100/200/400, VDC 250 Available Mounting Method Fasten With Screws Connection Method Embedded Type
Rated insulation voltage(V) AC690 Reverse Connections Applicable

Additional Products in this Category

Customers Who Viewed This Item Also Viewed

Tech Support

Third-party Brand
Tel:038-959200 Press 7 / FAX:038-959288
9:00 - 18:00 (Monday - Friday)