(!) Since support from Microsoft will end on January 14 2020, Windows 7 user might not be able to use MISUMI website effectively. Please consider to update your system as ‘MISUMI Website system requirement’.
Select part number to Order Now/ Add to Cart
Mitsubishi thermal relay TH-T series
[Features]
· Great satisfaction, condensed into a small unit.
· Further evolution of the Mitsubishi Electric electromagnetic switch.
· Can use to detect motor overload and locking current.
· Product lineup by application, including overload open-phase protection type, time-lagged type, quick operating type, etc.
[Applications]
· Motor burnout protection.
Applicable to motor protection: can be used for standard motor overload and locking protection.
Easy current value setting: can directly set the motor current value. Adjust with a cross-head / straight-slot screwdriver.
Reset method change: easy to change between manual reset and automatic reset.
With 1a1b contact: can use different voltages for a and b contacts.
Terminal cover as standard equipment (TH-T18/TH-T50): Having a terminal cover as standard equipment reduces the time for customers to specify a separate model name or arrange for options. This reduces inventory and reduces cover costs. Safety has also improved for protecting the live parts.
Outline drawing
Contact Configuration
For combining with the following electromagnetic contactors.
TH-T18:S-T10, T12, T20 SD-T12, T20
Can use as single unit in combination with single unit mounting unit UT-HZ18.
Outline drawing
Contact Configuration
Cannot be used with single unit mounting.
Use the following connection conductor (sold separately) when combining with an electromagnetic contactor.
Combination with S-T35/T50 (BC), SD-T35/T50 (BC): UT-TH50
Outline drawing
Contact Configuration
Use the following connection conductor kit (sold separately) when combining with an electromagnetic contactor.
Combination with S (D) -T65/T80: BH559N350
Combination with S-T100: BH569N350
Combination with SD-T100: BH569N352
Outline drawing
Contact Configuration
Cannot be used with single unit mounting.
Use the following connection conductor kit (sold separately) when combining with an electromagnetic contactor.
Connection conductor kit (sold separately, model name: BH569N350) used
Combination with S (D) -T80: BH559N350
Combination with S-T100: BH569N350
Combination with SD-T100: BH569N352
Part Number |
---|
TH-T50 29A |
Part Number | Price | Name | Minimum Order Qty. | Volume Discount | Days to Ship | Motor capacity/nominal thermal nominal size 440 VAC (kW/A) | Coil rated voltage (V) | Auxiliary Contact | Representative Standard | Dimension length (mm) | Dimension width (mm) | Dimension thickness (mm) | Specifications | Frame Size | Finger protection/terminal cover | Nominal heater size (A) | Nominal heater size (A) | Settling current adjustment range (A) | Rated insulation voltage (V) | Rate Impulse voltage resistant (kV) | Rated current used level AC-15 (opening/closing AC electromagnetic contactor coil) a contact/b contact AC 24 V (A) | Rated current used level AC-15 (opening/closing AC electromagnetic contactor coil) a contact/b contact AC 120 V (A) | Rated current used level AC-15 (opening/closing AC electromagnetic contactor coil) a contact/b contact AC 240 V (A) | Rated current used level AC-15 (opening/closing AC electromagnetic contactor coil) a contact/b contact AC 550 V (A) | Rated current used level DC-13 (opening/closing direct current electromagnetic contactor coil) DC 24 V (A) | Rated current used level DC-13 (opening/closing direct current electromagnetic contactor coil) DC 110 V (A) | Rated current used level DC-13 (opening/closing direct current electromagnetic contactor coil) DC 220 V (A) | Application | Terminal screw size (main circuit/operating circuit) | Trip class | Trip free | Reset method | Operation display (lever display) | Manual trip check |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
฿ 578.00 ฿ 482.51 | THERMAL OVERLOAD RELAY | 1 Piece(s) | Same day | - | - | 1a1b | - | 72 | 74.3 | 83.5 | Standard/2 elements | T50 | Standard equipment | - | 29 | 24~34 | 690 | 6 | 2/3 | 2/3 | 1/2 | 0.3/0.3 | 1 | 0.2 | 0.1 | For electromagnetic switch | M5/M3.5 | 10A | Standard equipment | Manual/automatic switching possible | Standard equipment | Standard equipment |
Loading...
Please check the type/dimensions/specifications of the part TH-T50 29A in the Overload Relays TH-T Series series.
Part Number |
---|
TH-T18 0.17A |
TH-T18 0.24A |
TH-T18 0.35A |
TH-T50 42A |
TH-T50KP 29A |
TH-T65 15A |
Part Number | Price | Minimum Order Qty | Volume Discount | Days to Ship | Motor capacity/nominal thermal nominal size 440 VAC (kW/A) | Coil rated voltage (V) | Auxiliary Contact | Representative Standard | Dimension length (mm) | Dimension width (mm) | Dimension thickness (mm) | Specifications | Frame Size | Finger protection/terminal cover | Nominal heater size (A) | Nominal heater size (A) | Settling current adjustment range (A) | Rated insulation voltage (V) | Rate Impulse voltage resistant (kV) | Rated current used level AC-15 (opening/closing AC electromagnetic contactor coil) a contact/b contact AC 24 V (A) | Rated current used level AC-15 (opening/closing AC electromagnetic contactor coil) a contact/b contact AC 120 V (A) | Rated current used level AC-15 (opening/closing AC electromagnetic contactor coil) a contact/b contact AC 240 V (A) | Rated current used level AC-15 (opening/closing AC electromagnetic contactor coil) a contact/b contact AC 550 V (A) | Rated current used level DC-13 (opening/closing direct current electromagnetic contactor coil) DC 24 V (A) | Rated current used level DC-13 (opening/closing direct current electromagnetic contactor coil) DC 110 V (A) | Rated current used level DC-13 (opening/closing direct current electromagnetic contactor coil) DC 220 V (A) | Application | Terminal screw size (main circuit/operating circuit) | Trip class | Trip free | Reset method | Operation display (lever display) | Manual trip check |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
฿ 498.00 | 1 Piece(s) | Same day | - | - | 1a1b | - | 55 | 45 | 76.5 | Standard/2 elements | T18 | Standard equipment | - | 0.17 | 0.14~0.22 | 690 | 6 | 2/2 | 2/2 | 1/1 | 0.3/0.3 | 0.5 | 0.2 | 0.1 | For electromagnetic switch | M3.5/M3.5 | 10A | Standard equipment | Manual/automatic switching possible | Standard equipment | Standard equipment | ||
฿ 498.00 | 1 Piece(s) | Same day | - | - | 1a1b | - | 55 | 45 | 76.5 | Standard/2 elements | T18 | Standard equipment | - | 0.24 | 0.2~0.32 | 690 | 6 | 2/2 | 2/2 | 1/1 | 0.3/0.3 | 0.5 | 0.2 | 0.1 | For electromagnetic switch | M3.5/M3.5 | 10A | Standard equipment | Manual/automatic switching possible | Standard equipment | Standard equipment | ||
฿ 498.00 | 1 Piece(s) | Same day | - | - | 1a1b | - | 55 | 45 | 76.5 | Standard/2 elements | T18 | Standard equipment | - | 0.35 | 0.28~0.42 | 690 | 6 | 2/2 | 2/2 | 1/1 | 0.3/0.3 | 0.5 | 0.2 | 0.1 | For electromagnetic switch | M3.5/M3.5 | 10A | Standard equipment | Manual/automatic switching possible | Standard equipment | Standard equipment | ||
฿ 578.00 | 1 Piece(s) | Same day | - | - | 1a1b | - | 72 | 74.3 | 83.5 | Standard/2 elements | T50 | Standard equipment | - | 42 | 34~50 | 690 | 6 | 2/3 | 2/3 | 1/2 | 0.3/0.3 | 1 | 0.2 | 0.1 | For electromagnetic switch | M5/M3.5 | 10A | Standard equipment | Manual/automatic switching possible | Standard equipment | Standard equipment | ||
฿ 883.00 | 1 Piece(s) | 72 Day(s) | - | - | 1a1b | - | 72 | 74.3 | 83.5 | 3 elements (2E) | T50 | Standard equipment | - | 29 | 24~34 | 690 | 6 | 2/3 | 2/3 | 1/2 | 0.3/0.3 | 1 | 0.2 | 0.1 | For electromagnetic switch | M5/M3.5 | 10A | Standard equipment | Manual/automatic switching possible | Standard equipment | Standard equipment | ||
฿ 852.00 | 1 Piece(s) | 72 Day(s) | - | - | 1a1b | - | 57 | 89 | 83.5 | Standard/2 elements | T65 | NA | - | 15 | 12~18 | 690 | 6 | 2/3 | 2/3 | 1/2 | 0.5/1 | 1 | 0.2 | 0.1 | For electromagnetic switch | M6/M4 | 10 | Standard equipment | Manual/automatic switching possible | Standard equipment | Standard equipment |