Solid-state Timer H3CR-F / -G / -H

Caution
Product Description
Series includes twin timers, star delta timers, and power OFF-delay timers.
[Features]
· Because the time unit can be separately set for ON time and OFF time, combinations of long term ON or OFF and short time ON or OFF are possible.
· Product range includes 2 types of operational modes: start flicker ON and start flicker OFF.
· Power supplies for low voltage (24 to 48 V AC / 12 to 48 V DC) and high voltage (100 to 240 V AC / 100 to 125 V AC) can be freely selected.
· 24 types of time ranges can be selected from 0.05 seconds to 300 hours.
· Instantaneous output for zero set value is possible.
[Applications]
· The timer acts as control equipment, switching the output signal at the preset time after the start signal is input.
· Can be used for all kinds of industrial equipment.
Solid-State Timer Specifications
Catalog product
H3CR-F /-G / -H external appearance
Series H3CR-F Twin Timer Performance
Because the time units enable separate ON time and OFF time setting, combinations of long term ON or OFF and short time ON or OFF are possible.
Product range includes 2 types of operational modes: start flicker ON and start flicker OFF.
Power supplies for low voltage (24 to 48 V AC / 12 to 48 V DC) and high voltage (100 to 240 V AC / 100 to 125 V AC) can be freely selected.
24 types of time ranges can be selected, from 0.05 seconds to 300 hours.
Instantaneous output for zero set value is possible. There is instantaneous output by turning the scale in the 0 direction, making it easy to confirm sequence operations, etc.
Complies with UL, CSA, NK, LR, and CCC, and is EN61812-1 compliant. Conforms to the CE mark.
H3CR-G Star Delta Timer Performance
4 types of time ranges can be selected with a single device, from 0.5 seconds to 120 seconds.
Complies with UL, CSA, NK, and LR, and is EN61812-1 compliant. Conforms to CE mark, CCC*
*Series H3CR-G8L-30/-G8EL-31 are not compliant with safety standards.
Series H3CR-H Power Supply OFF Delay Timer
4 types of time ranges can be selected for each series, from 0.05 seconds to 12 seconds for the S series and from 0.05 minutes to 12 minutes for the M series.
Complies with UL, CSA, NK, and LR, and is EN61812-1 compliant. Conforms to CE mark, CCC.
Solid-State Timer Performance
| Variations In Operating Time | ±0.2% (percentage relative to maximum scale) or less (±0.2%, ±10 ms or less in the 1.2‑s, 3‑s range) | |
|---|---|---|
| Set Error | ±5% (percentage relative to maximum scale) ±50 ms or less | |
| Recovery Time | 0.1 s Or Less | |
| Voltage Effect | ±0.2% (percentage relative to maximum scale) or less (±0.2%, ±10 ms or less in the 1.2‑s, 3‑s range) | |
| Temperature Effect | ±1% (percentage relative to maximum scale) or less (±1%, ±10 ms or less in the 1.2‑s, 3‑s range) | |
| Insulation Resistance | 100 MΩ or more (at 500 V DC megger) | |
| Withstand Voltage | 2,000 V AC, 50/60 Hz, 1 min (between charging metal part and non-charging metal part) 2,000 V AC, 50/60 Hz, 1 min (between control output and operation circuit) 2,000 V AC, 50/60 Hz, 1 min (between different pole contacts) 1,000 V AC, 50/60 Hz, 1 min (between discontinuous contacts) | |
| Impulse Voltage | 5 kV (between power supply terminals); however, 1 kV for 24 to 48 V AC / 12 to 48 V DC types 5 kV (between conductive part terminal and exposed non-charging metal part) However, 1.5 kV for 24 to 48 V AC / 12 to 48 V DC types | |
| Noise Resistance | Square-wave noise by noise simulator (pulse width 100 ns/1 μs rise 1 ns) ±1.5 kV (between power supply terminals) | |
| Electrostatic Strength | 8 kV (Malfunction) 15 kV (Destruction) | |
| Vibration | Endurance | 10 to 55 Hz, half amplitude 0.75 mm, 3 directions, 2 h each |
| Malfunction | 10 to 55 Hz, half amplitude 0.5 mm, 3 directions, 10 min each | |
| Shock | Endurance | 980 m/s2, 6 directions, 3 times each |
| Malfunction | 98 m/s2, 6 directions, 3 times each | |
| Life | Mechanical | 20 million operations or more (no load, switching frequency 1,800 operations/h) |
| Electrical | 100,000 operations or more (250 V AC, 5 A, resistive load, switching frequency 1,800 operations/h)* | |
| Protection Structure | IP40 (Panel Surface) | |
| Mass | Approx. 100 g | |
Solid-State Timer External Shape And Dimensional Drawing

Series H3CR-F, H3CR-FN external shape

Series H3CR-F, H3CR-FN dimensional drawing
- *Refer to the catalog for external shapes and dimensional drawings for model numbers other than those listed above.