(!) Since support from Microsoft will end on January 14 2020, Windows 7 user might not be able to use MISUMI website effectively. Please consider to update your system as ‘MISUMI Website system requirement’.
Select part number to Order Now/ Add to Cart
Suitable for auxiliary power supply of relay and sensor inside a control panel.
[Features]
· Compact type with 90 mm height and 100 mm depth.
· 10 W / 20 W type is 22.5 mm width contributing to space saving.
· Applied to 35 mm DIN rails.
· Screw type terminals to make connections easy.
· Resin case (10 to 100 W).
Part Number |
---|
MDR-10-5 |
MDR-10-12 |
MDR-20-5 |
MDR-20-12 |
MDR-40-5 |
MDR-40-12 |
MDR-60-5 |
MDR-60-12 |
MDR-100-12 |
Part Number | Price | Name | Minimum Order Qty. | Volume Discount | Days to Ship | Capacity (W) | Output voltage (Single only) | Rated output current (single only) (A) | Representative Standard | Dimension height (mm) | Dimension width (mm) | Rated output current 2 for DC 12 V (A) | Rated output current 3 for DC 5 V (A) | AC Input Voltage Range | AC Input current (Maximum) | DC adjustment range | Effi. | Overload protection | Over voltage protection | Withstand Voltage | Operating temperature | Safety Standard | EMC standards |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
฿ 568.08 ฿ 486.96 | SWITCHING POWER SUPPLY | 1 Piece(s) | 65 Day(s) | 10 | DC5V | 2 | CE / UL / CUL / TUV | 22.5 ~ 90 | 22.5 ~ 90 | - | 2 | 85~264VAC; 120~370VDC | Cold start, 35A at 115VAC, 70A at 230VAC | Fixed | 77% | >105% hiccup mode, auto-recovery | 115%~135% rated output voltage | I/P-O/P:3kVAC, I/P-FG:2kVAC, 1minute | -20~+70°C (refer to output derating curve) | UL508, TUV EN60950-1 approved; MDR-40/60 also approved for UL60950-1, ANSI/ISA 12.12.01-2013 Class I, Div. 2 Group A, B, C, D Hazardous Locations T4 | EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 heavy industry level (MDR-40/60/100) | ||
฿ 652.63 | SWITCHING POWER SUPPLY | 1 Piece(s) | 3 Day(s) | 10 | DC12V | 0.84 | CE / UL / CUL / TUV | 22.5 ~ 90 | 22.5 ~ 90 | 0.84 | - | 85~264VAC; 120~370VDC | Cold start, 35A at 115VAC, 70A at 230VAC | Fixed | 81% | >105% hiccup mode, auto-recovery | 115%~135% rated output voltage | I/P-O/P:3kVAC, I/P-FG:2kVAC, 1minute | -20~+70°C (refer to output derating curve) | UL508, TUV EN60950-1 approved; MDR-40/60 also approved for UL60950-1, ANSI/ISA 12.12.01-2013 Class I, Div. 2 Group A, B, C, D Hazardous Locations T4 | EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 heavy industry level (MDR-40/60/100) | ||
฿ 646.00 ฿ 553.69 | SWITCHING POWER SUPPLY | 1 Piece(s) | 2 Day(s) | 20 | DC5V | 3 | CE / UL / CUL / TUV | 22.5 ~ 90 | 22.5 ~ 90 | - | 3 | 85~264VAC; 120~370VDC | Cold start, 20A at 115VAC, 40A at 230VAC | ±10% rated output voltage | 76% | 105%~160% constant current limiting, auto-recovery | 115%~135% rated output voltage | I/P-O/P:3kVAC, I/P-FG:2kVAC, 1minute | -20~+70°C (refer to output derating curve) | UL508, TUV EN60950-1 approved; MDR-40/60 also approved for UL60950-1, ANSI/ISA 12.12.01-2013 Class I, Div. 2 Group A, B, C, D Hazardous Locations T4 | EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 heavy industry level (MDR-40/60/100) | ||
฿ 646.00 ฿ 553.75 | SWITCHING POWER SUPPLY | 1 Piece(s) | Same day | 20 | DC12V | 1.67 | CE / UL / CUL / TUV | 22.5 ~ 90 | 22.5 ~ 90 | 1.67 | - | 85~264VAC; 120~370VDC | Cold start, 20A at 115VAC, 40A at 230VAC | ±10% rated output voltage | 80% | 105%~160% constant current limiting, auto-recovery | 115%~135% rated output voltage | I/P-O/P:3kVAC, I/P-FG:2kVAC, 1minute | -20~+70°C (refer to output derating curve) | UL508, TUV EN60950-1 approved; MDR-40/60 also approved for UL60950-1, ANSI/ISA 12.12.01-2013 Class I, Div. 2 Group A, B, C, D Hazardous Locations T4 | EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 heavy industry level (MDR-40/60/100) | ||
฿ 990.79 | SWITCHING POWER SUPPLY | 1 Piece(s) | 3 Day(s) | 40 | DC5V | 6 | CE / CUL / TUV | 90 | 40 | - | 6 | - | - | - | - | - | - | - | - | - | - | ||
฿ 855.67 ฿ 733.39 | SWITCHING POWER SUPPLY | 1 Piece(s) | 65 Day(s) | 40 | DC12V | 3.33 | CE / UL / CUL / TUV | 40 ~ 90 | 40 ~ 90 | 3.33 | - | 85~264VAC; 120~370VDC | Cold start, 30A at 115VAC, 60A at 230VAC | 0~+20% rated output voltage | 86% | 105%~150% constant current limiting, auto-recovery | 125%~150% rated output voltage | I/P-O/P:3kVAC, I/P-FG:2kVAC, 1minute | -20~+70°C (refer to output derating curve) | UL508, TUV EN60950-1 approved; MDR-40/60 also approved for UL60950-1, ANSI/ISA 12.12.01-2013 Class I, Div. 2 Group A, B, C, D Hazardous Locations T4 | EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 heavy industry level (MDR-40/60/100) | ||
฿ 935.00 ฿ 801.39 | SWITCHING POWER SUPPLY | 1 Piece(s) | 2 Day(s) | 60 | DC5V | 10 | CE / CUL / TUV | 90 | 40 | - | 10 | - | - | - | - | - | - | - | - | - | - | ||
฿ 935.00 ฿ 801.39 | SWITCHING POWER SUPPLY | 1 Piece(s) | Same day | 60 | DC12V | 5 | CE / UL / CUL / TUV | 40 ~ 90 | 40 ~ 90 | 5 | - | 85~264VAC; 120~370VDC | Cold start, 30A at 115VAC, 60A at 230VAC | 0~+20% rated output voltage | 86% | 105%~150% constant current limiting, auto-recovery | 125%~150% rated output voltage | I/P-O/P:3kVAC, I/P-FG:2kVAC, 1minute | -20~+70°C (refer to output derating curve) | UL508, TUV EN60950-1 approved; MDR-40/60 also approved for UL60950-1, ANSI/ISA 12.12.01-2013 Class I, Div. 2 Group A, B, C, D Hazardous Locations T4 | EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 heavy industry level (MDR-40/60/100) | ||
฿ 1,615.00 ฿ 1,384.22 | SWITCHING POWER SUPPLY | 1 Piece(s) | 65 Day(s) | 100 | DC12V | 7.5 | CE / UL / CUL / TUV | 55 ~ 90 | 55 ~ 90 | 7.5 | - | 85~264VAC; 120~370VDC | Cold start, 30A at 115VAC, 60A at 230VAC | 0~+20% rated output voltage | 83% | 105%~150% constant current limiting, auto-recovery | 125%~150% rated output voltage | I/P-O/P:3kVAC, I/P-FG:2kVAC, 1minute | -10~+60°C | UL508, TUV EN60950-1 approved; MDR-40/60 also approved for UL60950-1, ANSI/ISA 12.12.01-2013 Class I, Div. 2 Group A, B, C, D Hazardous Locations T4 | EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 heavy industry level (MDR-40/60/100) |
Loading...
Shape | DIN rail direct attachment | Single/multi | Single | Input Voltage | AC/DC |
---|---|---|---|---|---|
Input/output terminal shape | European format | Dimension depth(mm) | 100 |
How can we improve?
How can we improve?