An input/output expansion block that can receive power supply from a basic power supply unit.
[Features]
· Can expand input by 16 points.
· Can be connected to the back of a basic unit or expansion unit.
[Applications]
· Convenient for expanding input/output, receiving power supply from a basic unit or expansion unit.
FX2N-16EX
FX2N-16EX-C
FX2N-16EYR
FX2N-16EYT
FX2N-16EYT-C
FX2N-8EX
FX2N-8EYR
FX2NC-16EX-T
Ambient Temperature | 0 To 55°C - When operating -25 To 75°C - When saving | ||
---|---|---|---|
Relative Humidity | 5 To 95% RH (No Condensation) - When Operating | ||
Vibration-resistant | When Mounting To DIN Rail | Frequency: 10 To 57 Hz | Single Amplitude: 0.035 mm 10 Times In Each Direction X, Y, Z (Total 80 Minutes Each) Assessment Standards Are Based On IEC61131-2 |
Frequency: 57 To 150 Hz | Acceleration: 4.9 m/s2 10 Times In Each Direction X, Y, Z (Total 80 Minutes Each) Assessment Standards Are Based On IEC61131-2 | ||
When Mounting Directly | Frequency: 10 To 57 Hz | Single Amplitude: 0.075 mm 10 Times In Each Direction X, Y, Z (Total 80 Minutes Each) Assessment Standards Are Based On IEC61131-2 | |
Frequency: 57 To 150 Hz | Acceleration: 9.8 m/s2 10 Times In Each Direction X, Y, Z (Total 80 Minutes Each) Assessment Standards Are Based On IEC61131-2 | ||
Shock-Resistant | 147 m/s2, For A Half-sine Pulse Three Times In Directions X, Y, And Z For A Duration Of 11 ms. The Assessment Standards Are Based On IEC611131-2 | ||
Noise Resistant | Achieved Through A Noise Simulator With A Noise Voltage Of 1,000 Vp-p, Noise Width Of 1 μs, Rise Time Of 1 ns, And Frequency Of 30 To 100 Hz | ||
Voltage Resistance | Between The Expansion Input Block Input Terminal And Earth Terminal: 1 Minute At 500 V AC | ||
Insulation Resistance | Between The Expansion Input Block Input Terminal And Earth Terminal: 5 MΩ Or More At 500 V DC On An Insulation Resistance Meter | ||
Circumstances Of Use | When There Is Not A Large Amount Of Conductive Dust, And No Corrosion Or Flammable Gas | ||
Frequency Of Use | Cannot Be Used In Pressurized Environments Below 2,000 m. Doing So May Cause Failures. |
Voltage Resistance | Between The Expansion Input Block Input Terminal And Earth Terminal: 1 Minute At 500 V AC |
---|---|
Insulation Resistance | Between The Expansion Input Block Input Terminal And Earth Terminal: 5 MΩ Or More At 500 V DC On An Insulation Resistance Meter |
Voltage Resistance | Between The Expansion Input Block Input Terminal And Earth Terminal: 1 Minute At 500 V AC |
---|---|
Insulation Resistance | Between The Expansion Input Block Input Terminal And Earth Terminal: 5 MΩ Or More At 500 V DC On An Insulation Resistance Meter |
Voltage Resistance | Between The Expansion Output Block Output Terminal And Earth Terminal: 1 Minute At 1,500 V AC |
---|---|
Insulation Resistance | Between The Expansion Output Block Output Terminal (Relay) And Earth Terminal: 5 MΩOr More At 500 V DC On An Insulation Resistance Meter |
Voltage Resistance | Between The Expansion Output Block Output Terminal (Transistor) And Earth Terminal: 1 Minute At 500 V AC |
---|---|
Insulation Resistance | Between The Expansion Output Block Output Terminal (Transistor) And Earth Terminal: 5 MΩ Or More At 500 V DC On An Insulation Resistance Meter |
Voltage Resistance | Between The Expansion Output Block Output Terminal (Transistor) And Earth Terminal: 1 Minute At 500 V AC |
---|---|
Insulation Resistance | Between The Expansion Output Block Output Terminal (Transistor) And Earth Terminal: 5 MΩ Or More At 500 V DC On An Insulation Resistance Meter |
Voltage Resistance | Between The Expansion Input Block Input Terminal And Earth Terminal: 1 Minute At 500 V AC |
---|---|
Insulation Resistance | Between The Expansion Input Block Input Terminal And Earth Terminal: 5 MΩ Or More At 500 V DC On An Insulation Resistance Meter |
Voltage Resistance | Between The Expansion Output Block Output Terminal And Earth Terminal: 1 Minute At 1,500 V AC |
---|---|
Insulation Resistance | Between The Expansion Output Block Output Terminal (Relay) And Earth Terminal: 5 MΩOr More At 500 V DC On An Insulation Resistance Meter |
Ambient Temperature | 0 To 55°C - When Operating -20 To 70°C - When Saving | ||
---|---|---|---|
Relative Humidity | 35 To 85% RH (No Condensation) - When Operating | ||
Vibration-resistant | When Mounting To DIN Rail | Frequency: 10 To 57 Hz | Single Amplitude: 0.035 mm 10 Times In Each Direction X, Y, Z (Total 80 Minutes Each) Assessment Standards Are Based On IEC61131-2 |
Frequency: 57 To 150 Hz | Acceleration: 4.9 m/s2 10 Times In Each Direction X, Y, Z (Total 80 Minutes Each) Assessment Standards Are Based On IEC61131-2 | ||
Shock-Resistant | 147 m/s2, For A Half-sine Pulse Three Times In Directions X, Y, And Z For A Duration Of 11 ms. The Assessment Standards Are Based On IEC611131-2 | ||
Noise Resistant | Achieved Through A Noise Simulator With A Noise Voltage Of 1,000 Vp-p, Noise Width Of 1 μs, Rise Time Of 1 ns, And Frequency Of 30 To 100 Hz | ||
Voltage Resistance | Between The Expansion Input Block Input Terminal And Earth Terminal: 1 Minute At 500 V AC | ||
Insulation Resistance | Between The Expansion Input Block Input Terminal And Earth Terminal: 5 MΩ Or More At 500 V DC On An Insulation Resistance Meter |
Part Number |
---|
FX5-C16EX/DS |
Part Number | Price | Name | Minimum Order Qty. | Volume Discount | Days to Ship | Number Of Inputs | Rated Input Voltage (V) | Number of Outputs | Output Format | Representative Standard | Features | Applicable sequencer | Number Of Inputs (Point) | Number of Outputs (Point) | Terminal shape | Type of unit | Type of unit | Resistance Load (A/1 Point) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
฿ 5,320.00 ฿ 4,559.77 | PLC(INPUTOUTPUTUNIT) | 1 Piece(s) | Same day | 16 | DC24V | NA | - | CE / UL / CUL | - | FX5U / FX5UC | 16 | NA | Connector | - | Input | - |
Loading...
Please check the type/dimensions/specifications of the part FX5-C16EX/DS in the MELSEC-F Input/Output Expansion Block series.
Part Number |
---|
FX2N-16EYR |
FX2N-16EYS |
FX2N-16EYT |
FX5-C16EYT/D |
FX5-C16EYT/DSS |
FX5-C32ET/D |
Part Number | Price | Minimum Order Qty | Volume Discount | Days to Ship | Number Of Inputs | Rated Input Voltage (V) | Number of Outputs | Output Format | Representative Standard | Features | Applicable sequencer | Number Of Inputs (Point) | Number of Outputs (Point) | Terminal shape | Type of unit | Type of unit | Resistance Load (A/1 Point) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
฿ 5,133.00 | 1 Piece(s) | Same day | - | NA | 16 | Relay contact output | - | - | FX3UC / FX3GC / FX1NC / FX2NC / FX3G / FX3U / FX1N / FX2N | NA | 16 | Vertical Type Terminal Block | Output | - | - | ||
฿ 5,955.00 | 1 Piece(s) | Same day | NA | NA | 16 | Triac output | CE / UL | - | FX3UC / FX3GC / FX3G / FX3U | NA | 16 | - | - | Output | - | ||
฿ 5,000.00 | 1 Piece(s) | Same day | - | NA | 16 | Transistor / sync output | - | - | FX3UC / FX3GC / FX1NC / FX2NC / FX3G / FX3U / FX1N / FX2N | NA | 16 | Vertical Type Terminal Block | Output | - | 0.5A/1 piece | ||
฿ 6,212.00 | 1 Piece(s) | 6 Day(s) | NA | NA | 16 | Transistor / sync output | CE / CUL / UL | - | FX5U / FX5UC | NA | 16 | Connector | - | Output | - | ||
฿ 6,937.00 | 1 Piece(s) | 29 Day(s) | NA | NA | 16 | Transistor / source output | CE / CUL / UL | - | FX5U / FX5UC | NA | 16 | Connector | - | Output | - | ||
฿ 11,755.00 | 1 Piece(s) | 6 Day(s) | - | DC24V | - | Transistor / sync output | CE / CUL / UL | - | FX5U / FX5UC | 16 | 16 | Connector | - | Output | - |