A step data input type electric actuator.
[Features]
· Already set with actuator data when shipped. (Actuator and controller are provided as a set)
· Easy mode for simple setting and normal mode for detailed setting.
· Teaching box, controller setting software.
· Number of step data: 64 points.
· Completion signal: (INP) output.
Step motor (24‑V DC servo) LECP6 Series external appearance
Servo motor (24 V DC) LECA6 Series external appearance
Item | LECP6 | LECA6 |
---|---|---|
Compatible Motor | Step motor (24‑V DC servo) | Servo motor (24 V DC) |
Power Supply Specifications Note 1: | Power voltage: 24 V DC ±10% Note 2: [Including motor drive power, control power, stop, lock release] | Power voltage: 24 V DC ±10% Note 2: [Including motor drive power, control power, stop, lock release] |
Parallel Input | 11 inputs (photo-coupler isolation) | |
Parallel Output | 13 outputs (photo-coupler isolation) | |
Compatible Encoder | Incremental A/B phase (800 pulses/rotation) | Incremental A/B (800 pulses/rotation) / Z phase |
Serial Communication | RS485 (Modbus protocol compliant) | |
Memory | EEPROM | |
LED Indicator | LED (green/red), 1 pc. each | |
Lock Control | With forced-lock release terminal Note 3: | |
Cable Length [m] | I/O cable: 5 or less, Actuator cable: 20 or less | |
Cooling System | Natural air cooling | |
Operating Temperature Range [°C] | 0 to 40 (no freezing) | |
Operating Humidity Range [%RH] | 90 or less (no condensation) | |
Storage Temperature Range [°C] | -10 to 60 (no freezing) | |
Storage Humidity Range [%RH] | 90 or less (no condensation) | |
Insulation Resistance [MΩ] | Between housing and SG terminal: 50 (500 V DC) | |
Weight [g] | 150 (screw mounting type), 170 (DIN rail mounting type) |
Note 1: Use a power supply other than the "inrush current prevention type" for the controller input DC power supply. When conformity to UL is required, use with a UL1310 Class 2 power supply.
Note 2: The power consumption changes depending on the actuator model. Refer to the actuator specifications for more details.
Note 3: Compatible with non-magnetizing lock.
(Units: mm)
Screw mounting (LEC□6□□-□) dimensional drawing
DIN rail mounting (LEC□6□□D-□) dimensional drawing
*Refer to the manufacturer's catalog for DIN rail L dimensions and part numbers.
Screw mounting (LEC□6□□-□) (use 2 × M4 screws)
DIN rail mounting (LEC□6□□D-□) (use DIN rail)
Power supply plug for LECP6 (image of LEC-D-1-1)
CN1 Power Supply Connector Terminals for LECP6
(FK-MC0.5/5-ST-2.5)
Terminal Name | Function | Function Details |
---|---|---|
0 V | Common supply (-) | M 24‑V terminal / C 24‑V terminal / EMG terminal / BK RLS terminal are common (-). |
M24V | Motor power supply (+) | Motor power supply (+) side supplies to the controller. |
C24V | Control power supply (+) | Control power supply (+) side supplies to the controller. |
EMG | Stop (+) | Input (+) for releasing the stop. |
BK RLS | Lock release (+) | Input (+) for releasing the lock. |
Power supply plug for LECA6 (image of LEC-D-1-2)
CN1 Power Supply Connector Terminals for LECA6
(FK-MC0.5/7-ST-2.5)
Terminal Name | Function | Function Details |
---|---|---|
0 V | Common supply (-) | M 24‑V terminal / C 24‑V terminal / EMG terminal / BK RLS terminal are common (-). |
M24V | Motor power supply (+) | Motor power supply (+) side supplies to the controller. |
C24V | Control power supply (+) | Control power supply (+) side supplies to the controller. |
EMG | Stop (+) | Input (+) for releasing the stop. |
BK RLS | Lock release (+) | Input (+) for releasing the lock. |
RG+ | Regenerative output 1 | Regenerative output terminals for external connection. (Not necessary to connect them in the combination with the LE Series standard specifications.) |
RG- | Regenerative output 2 |
*Power supply plug is an accessory.
LEC□6N□□-□ (NPN) wiring diagram
LEC□6P□□-□ (PNP) wiring diagram
Input Signal Details
Name | Details |
---|---|
COM+ | Connects the 24‑V side of the 24‑V DC power supply for the input/output signal |
COM- | Connects the 0‑V side of the 24‑V DC power supply for the input/output signal |
IN0 to IN5 | Step data specified Bit No. (Input is instructed for the combinations IN0 to 5) |
SETUP | Instruction to return to origin |
HOLD | Operation is temporarily stopped |
DRIVE | Instruction to drive |
RESET | Alarm reset and interruption of operation |
SVON | Servo ON instruction |
Output Signal Details
Name | Details |
---|---|
OUT0 to OUT5 | Outputs the step data no. during operation |
BUSY | Outputs when the actuator is moving |
AREA | Outputs within the step data area output setting range |
SETON | Outputs when returning to origin |
INP | ON when target position or target force is reached (Turns ON when the positioning or pushing is completed) |
SVRE | Outputs when servo is ON |
*ESTOP Note: | No output when EMG stop is instructed |
*ALARM Note: | No output when alarm is generated |
Note: Signal of negative-logic circuit (N.C.)
Part Number |
---|
LECA6P3-LEFS16RAB-150 |
Part Number | Price | Name | Minimum Order Qty. | Volume Discount | Days to Ship | Input Power Supply | Position Detection | I/O Module | Size | Motor type | Step data (points) | Actuator/cable type | I/O cable length / communication plug (m) | Controller/driver mounting method |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
฿ 12,388.32 | SMC AIR CYLINDER | 1 Piece(s) | 25 Day(s) | DC24V | Incremental | PNP | - | Servo motor (24 V DC) | 64 | LEFS16RAB-150 | 3 | Screw mounting type |
Loading...
Main Body, Peripheral Components | Peripheral Components |
---|
How can we improve?
How can we improve?