E2E Standard Type Proximity Sensor

Caution
Product Description
If you are looking for a proximity sensor, the E2E should be your first step.
[Features]
· The standard for detecting the presence of magnetic metals.
· Wide variety of types available.
Select the most appropriate model for the given conditions.
· For dealing with mutual interference, different frequency type also available.
· Displays excellent environmental resistance.
The standard cable is made of oil-resistant PVC.
The sensing surface is made of a material that is strong against machining oil.
· A cord protector to prevent wire breakage is used as standard.
_pages-to-jpg-0017_001.jpg)
Dimensional Drawing of OMRON Proximity Sensors
Pull-Out Cord Type OMRON Proximity Sensors (Shielded Type)
Pre-Wired Type OMRON Proximity Sensors (Non-Shielded Type)


insulated round cord φ4, 3-core (conductor cross-sectional area: 0.3mm2, insulator diameter: φ1.3mm) standard 2mBend-
resistant cord type is
vinyl insulated round cord φ4, 2-core (conductor cross-sectional area: 0.3mm2, insulator diameter: φ1.27mm) standard 2mVinyl
insulated round cord φ4, 3-core (conductor cross-sectional area: 0.3mm2, Proximity Sensors insulator diameter: φ1.27mm) standard 2mOil-
resistant reinforced cord type is
polyurethane insulated round cord φ4, 2-core (conductor cross-sectional area: 0.3mm2, insulator diameter: φ1.3mm)
standard 2mCord
extension (single metal conduit) up to 200m
*2.D1 type: operation indicator (red), setting indicator (green), D2/E/F type: operation indicator (red)
* For information on model numbers other than those listed above, please refer to the digital catalog.
2mVinyl insulated round cord φ4, 3 cores (conductor cross-sectional area: 0.3mm2, Proximity Sensors insulator diameter: φ1.3mm) standard length 2mFlexible
cord type is
vinyl insulated round cord φ4, 2 cores (conductor cross-sectional area: 0.3mm2, insulator diameter: φ1.27mm) standard length
2mVinyl insulated round cord φ4, 3 cores (conductor cross-sectional area: 0.3mm2, Proximity Sensors insulator diameter: φ1.27mm) standard length 2mCord
extension (single metal conduit) maximum 200m
*2.D1 type: operation indicator (red), setting indicator (green), D2/E/F types: operation indicator (red)
* For information on model numbers other than those mentioned above, please refer to the digital catalog.
Specification Table of OMRON Proximity Sensors
OMRON Proximity Sensors Ratings/Performance
Proximity Sensors DC 2-wire type (E2E-X□D□)
| Proximity Sensors item | size | M8 | M12 | M18 | M30 | ||||
|---|---|---|---|---|---|---|---|---|---|
| shield | shield | Unshielded | shield | Unshielded | shield | Unshielded | shield | Unshielded | |
| Model number | Model E2E-X2D□ | Model E2E-X4MD□ | Model E2E-X3D□ | Model E2E-X8MD□ | Model E2E-X7D□ | Model E2E-X14MD□ | Model E2E-X10D□ | Model E2E-X20MD□ | |
| Proximity Sensors Detection distance | 2mm±10% | 4mm±10% | 3mm±10% | 8mm±10% | 7mm±10% | 14mm±10% | 10mm±10% | 20mm±10% | |
| Set distance*1 | 0 to 1.6 mm | 0 to 3.2 mm | 0 to 2.4 mm | 0 to 6.4 mm | 0 to 5.6 mm | 0 to 11.2 mm | 0 to 8 mm | 0 to 16 mm | |
| Hysteresis | 15% or less of detection distance | 10% or less of the detection distance | |||||||
| Detectable Objects | Magnetic metal (non-magnetic metal reduces the detection distance. | ||||||||
| Standard detection object | Iron 8×8×1mm | Iron 20 x 20 x 1 mm | Iron 12 x 12 x 1 mm | Iron 30×30×1mm | Iron 18 x 18 x 1 mm | Iron 30×30×1mm | Iron 54×54×1mm | ||
| Response frequency*2 | 1.5kHz | 1kHz | 0.8kHz | 0.5kHz | 0.4kHz | 0.1kHz | |||
| Power supply voltage (operating voltage range) | Proximity Sensors Standard type: DC12 to 24V ripple (pp) 10% or less (DC10 to 30V) When using US type or connector type as UL certified product: DC12 to 24V ripple (pp) 10% or less (usage voltage range is also the same) | ||||||||
| Leakage current | 0.8mA or less | ||||||||
| Control Output | Opening and closing capacity | 3 to 100mA, diagnostic output 50mA [D1(5) S type only] | |||||||
| Residual voltage*3 | 3V or less (load current 100mA, cord length 2m, except M1J-T type only 5V or less) | ||||||||
| Indicator Light | D1 type: Operation indicator (red), setting indicator (green) D2 type: Operation indicator (red) | ||||||||
| Operation mode (when detecting object approaching) | D1 type: NO D2 type: NC | ||||||||
| Diagnostic output delay time | 0.3 to 1 s | ||||||||
| Protection Circuit | Surge absorption, load short circuit protection (both control output and diagnostic output) | ||||||||
| Ambient Temperature Range | Operating: -25 to +70°C Storage: -40 to +85°C (but do not freeze or condense) | ||||||||
| Ambient Humidity Range | During operation and storage: 35 to 95% RH (but no condensation) | ||||||||
| Temperature effects | Within ±15% of detection distance at +23°C within the temperature range of -25 to +70°C | Within ±10% of detection distance at +23°C within the temperature range of -25 to +70°C | |||||||
| Voltage Effects | Within ±1% of detection distance at rated power supply voltage within ±15% range | ||||||||
| Insulation resistance | 50MΩ or more (DC500V megger) between live parts and case | ||||||||
| Withstand voltage | AC1,000V 50/60Hz 1min Between live parts and case | ||||||||
| Vibration (durability) | 10 to 55Hz, double amplitude 1.5mm, 2h each in X, Y, and Z directions | ||||||||
| Impact (durability) | 500m/s2 10 times each in X, Y, and Z directions | 1,000m/s2 10 times each in X, Y, and Z directions | |||||||
| Protective structure | Pre-wired type, connector relay type: IEC standard IP67 Connector type: IEC standard IP67 | ||||||||
| Connection method | Pre-wired type (standard cord length 2m), connector type, relay connector type (standard cord length 300mm) | ||||||||
| Weight (packaged ) | Cord pull-out type | Approx. 60g | Approx. 70g | Approx. 130g | Approx. 175g | ||||
| Connector relay type | - | Approx. 40g | Approx. 70g | Approx. 110g | |||||
| Connector Type | Approx. 15g | Approx. 25g | Approx. 40g | Approx. 90g | |||||
| Material | case | Stainless steel (SUS303) | Brass, nickel plated | ||||||
| Detection surface | PBT | ||||||||
| Clamping Nut | Brass, nickel plated | ||||||||
| Toothed washer | Iron Zinc plating | ||||||||
| accessories | operating instructions | ||||||||
*1. The Proximity Sensors Use within the range where the green indicator light is on. (Excluding D2 type)
*2. The response frequency of the Proximity Sensors is an average value.
Measurement conditions are as follows: A standard detection object is used, the detection object interval is twice that of the standard detection object, and the set distance is 1/2 the detection distance.
*3. When using the M1J-T type, the residual voltage is 5V, so please check the interface conditions with the connected device before use.
* For information on model numbers other than those listed above, please refer to the digital catalog.